A question about whether the second part of clause 21.2 needs to be tested.

We know that clause 29.3.2 and clause 21.2 are two separate clauses and they are not very much related, which means that the product being assessed needs to fulfill both clauses if applicable.A reinforced insulation system consisting of three separate layers of insulating material or what could be considered a double insulation system, Each layer…

A question about clause 21.1 and detachable parts

21.1 Appliances shall have adequate mechanical strength and be constructed to withstand such rough handling that may be expected in normal use.Compliance is checked by applying blows to the appliance in accordance with test Ehb ofIEC 60068-2-75, the spring hammer test.The appliance is rigidly supported and three blows, having an impact energy of 0,5 J,…