{"id":2747,"date":"2025-10-02T10:30:43","date_gmt":"2025-10-02T08:30:43","guid":{"rendered":"https:\/\/gezhi-tech.com\/?p=2747"},"modified":"2025-10-02T10:31:06","modified_gmt":"2025-10-02T08:31:06","slug":"25-20-do-supply-cord-entering-the-metal-enclosure-need-an-additional-layer-of-insulation-at-the-vias","status":"publish","type":"post","link":"https:\/\/gezhi-tech.com\/de\/25-20-do-supply-cord-entering-the-metal-enclosure-need-an-additional-layer-of-insulation-at-the-vias\/","title":{"rendered":"25.20 Do supply cord entering the metal enclosure need an additional layer of insulation at the vias?"},"content":{"rendered":"<p>25.20: The conductors of the <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-supply-cord\/\" target=\"_blank\"><strong>supply cord<\/strong><\/a> <\/strong>for <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-type-y-attachment\/\" target=\"_blank\"><strong>type Y attachment<\/strong><\/a> <\/strong>and <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-type-z-attachment\/\" target=\"_blank\"><strong>type Z attachment<\/strong><\/a> <\/strong>shall be insulated from <strong>accessible metal parts <\/strong>by <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-basic-insulation\/\" target=\"_blank\"><strong>basic insulation<\/strong><\/a> <\/strong>for <strong>class 0 appliances<\/strong>, <strong>class 0I appliances <\/strong>and <strong>class I appliances, <\/strong>and by <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-basic-insulation-2\/\" target=\"_blank\"><strong>supplementary insulation<\/strong><\/a> <\/strong>for <strong>class II appliances<\/strong>. This insulation may be provided by the sheath of the <strong>supply cord <\/strong>or by other means. <\/p>\n\n\n\n<p>This clause should be considered with clause 16.3, generally condition, all most countries employed supply cord with <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-double-insulation\/\" target=\"_blank\"><strong>double insulation<\/strong><\/a> except those countries based on main power voltage less than 150V, such as Japan, America, Mexico etc.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"646\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/double-insulation-of-supply-cord-1024x646.jpg\" alt=\"\" class=\"wp-image-2751\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/double-insulation-of-supply-cord-1024x646.jpg 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/double-insulation-of-supply-cord-300x189.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/double-insulation-of-supply-cord-768x484.jpg 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/double-insulation-of-supply-cord.jpg 1067w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">double insulation of supply cord<\/figcaption><\/figure>\n\n\n\n<p>I guess most people would think that the white insulation enclosure on the outside of supply cord should be the sheath or other means. But it is not. Here, the supply cord do need an additional sheath or other means, please pay attention, a sheath is only required when the supply cord passes directly through the accessible metal enclosure of the appliance, because the first sentence of clause 25.20 mentions the insulating sheath between accessible metal parts and the supply cord.<\/p>\n\n\n\n<p>Why I could get such a conclusion? We could refer to clause 16.3, the following content:<\/p>\n\n\n\n<p><em>A test voltage is applied between <strong>accessible metal parts <\/strong>and the <strong>supply cord <\/strong>which is wrapped with metal foil at the point where the <strong>supply cord <\/strong>is located in an inlet bushing and where, for appliances having a <strong><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-type-x-attachment\/\" target=\"_blank\"><strong>type X attachment<\/strong><\/a><\/strong>, the <strong>supply cord <\/strong>is located in a cord guard or a cord anchorage with their clamping screws, if any, being tightened to two-thirds of the torque specified in Table 14. The test voltage is 1 250 V for <strong>class I appliances<\/strong><\/em> <em>and 1 750 V for <strong>class II appliances<\/strong>.<\/em><\/p>\n\n\n\n<p>Clause 16.3 requires that the supply cord be wrapped with a metal foil at the inlet before the electrical strength test. If there is no insulating sheath outside the power cord, the test will fail.<\/p>\n\n\n\n<p>Combining the requirements of two different clause of the standard, we can infer the standard&#8217;s intent.<\/p>\n\n\n\n<p>What type of sheath should be used? The standard does not require a sheath, other types are acceptable. The following photo show an acceptable structure.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"906\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/0feb2d77ae72f991f4319c2d43acf697-1024x906.jpg\" alt=\"\" class=\"wp-image-2748\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/0feb2d77ae72f991f4319c2d43acf697-1024x906.jpg 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/0feb2d77ae72f991f4319c2d43acf697-300x265.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/0feb2d77ae72f991f4319c2d43acf697-768x679.jpg 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/0feb2d77ae72f991f4319c2d43acf697.jpg 1279w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1022\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d-1024x1022.jpg\" alt=\"\" class=\"wp-image-2750\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d-1024x1022.jpg 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d-300x300.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d-150x150.jpg 150w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d-768x767.jpg 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/81556366cd33486cd3c4a81bcf10db3d.jpg 1279w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>The method shown in the image serves both as insulation and as a cable clamp.<\/p>\n\n\n\n<p>In the image below, because the supply cord via is made of non-metallic plastic, clause 25.20 is not applicable.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"586\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/90da1ba2cfaa9dab4685ca40dff5094c-1024x586.jpg\" alt=\"\" class=\"wp-image-2749\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/90da1ba2cfaa9dab4685ca40dff5094c-1024x586.jpg 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/90da1ba2cfaa9dab4685ca40dff5094c-300x172.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/90da1ba2cfaa9dab4685ca40dff5094c-768x440.jpg 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/10\/90da1ba2cfaa9dab4685ca40dff5094c.jpg 1279w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>25.20: The conductors of the <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-supply-cord\/\" target=\"_blank\"><strong>supply cord<\/strong><\/a> for <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-type-y-attachment\/\" target=\"_blank\"><strong>type Y attachment<\/strong><\/a> and <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-type-z-attachment\/\" target=\"_blank\"><strong>type Z attachment<\/strong><\/a> shall be insulated from accessible metal parts by <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-basic-insulation\/\" target=\"_blank\"><strong>basic insulation<\/strong><\/a> for class 0 appliances, class 0I appliances and class I appliances, and by <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-basic-insulation-2\/\" target=\"_blank\"><strong>supplementary insulation<\/strong><\/a> for class II appliances. This insulation may be provided by the sheath of the supply&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[27],"tags":[76,70],"class_list":["post-2747","post","type-post","status-publish","format-standard","hentry","category-supply-connection-and-external-flexible-cords","tag-insulation-system-comprising-both-basic-insulation-and-supplementary-insulation","tag-flexible-cord-for-supply-purposes-that-is-fixed-to-the-appliance"],"translation":{"provider":"WPGlobus","version":"3.0.1","language":"de","enabled_languages":["en","es","ar","de","ja","fr","ru","th","nl","it","fa","ko","pt","hi","ro","tr","vi","id","zu"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"nl":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"fa":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"ro":{"title":false,"content":false,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"zu":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/posts\/2747","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/comments?post=2747"}],"version-history":[{"count":2,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/posts\/2747\/revisions"}],"predecessor-version":[{"id":2753,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/posts\/2747\/revisions\/2753"}],"wp:attachment":[{"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/media?parent=2747"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/categories?post=2747"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gezhi-tech.com\/de\/wp-json\/wp\/v2\/tags?post=2747"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}