{"id":47,"date":"2024-06-24T07:55:21","date_gmt":"2024-06-24T05:55:21","guid":{"rendered":"https:\/\/gezhi-tech.com\/?p=47"},"modified":"2025-09-27T17:50:26","modified_gmt":"2025-09-27T15:50:26","slug":"8-1-5-protected-at-least-by-basic-insulation-before-installation-or-assembly","status":"publish","type":"post","link":"https:\/\/gezhi-tech.com\/es\/8-1-5-protected-at-least-by-basic-insulation-before-installation-or-assembly\/","title":{"rendered":"8.1.5 \u2013 Protegido al menos por aislamiento b\u00e1sico antes de la instalaci\u00f3n o montaje"},"content":{"rendered":"<br>\nLa cl\u00e1usula 8.1.1 menciona que la sonda de prueba debe usarse cuando el aparato est\u00e9 bajo &#8220;uso normal&#8221;, mientras que la cl\u00e1usula 8.1.5 se eval\u00faa antes de la instalaci\u00f3n. Productos como estos, que se entregan en varias partes, generalmente requieren instalaci\u00f3n in situ. &#8220;Vivo y nbsp;partes y nbsp;de y nbsp;empotrados y nbsp;electrodom\u00e9sticos, y nbsp;fijos y nbsp;electrodom\u00e9sticos y nbsp;y y nbsp;electrodom\u00e9sticos y nbsp;entregados y nbsp;en y nbsp;separados y nbsp;unidades, y nbsp;deber\u00e1n y nbsp;estar y nbsp;protegido y nbsp;en y nbsp;m\u00ednimo y nbsp;por y nbsp;b\u00e1sico y nbsp;aislamiento y nbsp;antes y nbsp;instalaci\u00f3n y nbsp;o y nbsp ;asamblea.&#8221; Aqu\u00ed surge un tipo de peligro durante la instalaci\u00f3n. Un ejemplo es el siguiente:<br>\n<br>\n<figure><br>\n<img decoding=\"async\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/AC-heating-element.png\" alt=\"\" style=\"width:645px;height:auto\"><\/figure><br>\n<br>\nUn producto de aire acondicionado con un calentador el\u00e9ctrico auxiliar en el aire acondicionado, que se instala en la unidad interior, la unidad interior y la unidad exterior est\u00e1n empaquetadas en dos partes separadas, y las dos partes se entregan juntas en el lugar del usuario. de uso. En el proceso de instalaci\u00f3n, si el suministro de energ\u00eda de la unidad interior se realiza a trav\u00e9s de la unidad exterior, entonces es posible que el instalador realice primero la conexi\u00f3n entre la unidad interior y la unidad exterior (tenga en cuenta que la conexi\u00f3n interior y exterior Los cables (cable de interconexi\u00f3n) ya est\u00e1n conectados a los terminales de la unidad interior antes de la distribuci\u00f3n), y luego energiza la unidad exterior para su puesta en servicio. Durante el proceso de puesta en servicio, es posible que el propio instalador u otros instaladores no se den cuenta de que algunos de los componentes de la unidad interior est\u00e1n realmente cargados el\u00e9ctricamente (porque la parte electrificada es la unidad exterior), y si estas partes cargadas el\u00e9ctricamente no est\u00e1n protegidas por un aislamiento b\u00e1sico. , existe riesgo de descarga el\u00e9ctrica. y nbsp;<br>\n<br>\nAqu\u00ed hay solo un ejemplo del calentador auxiliar el\u00e9ctrico del aire acondicionado, la mayor\u00eda de los puntos con problemas comunes son los terminales.<br><br>\n<br>\nEn la imagen de la izquierda a continuaci\u00f3n, puede ver que la unidad interior del aire acondicionado abre el panel frontal y hay una placa de cubierta de pl\u00e1stico en el lado derecho del interior que se sujeta en su lugar con tornillos, y debajo de la placa de cubierta est\u00e1n los terminales, y puede ver los terminales en la imagen de la derecha. La parte inferior del terminal tiene varios cables, que son el cable de interconexi\u00f3n conectado a la unidad exterior. si no tiene la placa de cubierta y nbsp; (el panel frontal es una parte removible y generalmente no se considera que est\u00e9 sustancialmente aislado), despu\u00e9s de completar la conexi\u00f3n de las unidades interior y exterior, as\u00ed como la conexi\u00f3n de la fuente de alimentaci\u00f3n a la unidad exterior. , los terminales de la unidad interior se cargar\u00e1n el\u00e9ctricamente y existe riesgo de electrocuci\u00f3n si no est\u00e1n protegidos por el panel de cubierta.<br>\n<br>\n\t\t<br>\n\t\t\t<style>\/*! elementor - v3.22.0 - 26-06-2024 *\/<br>\n.elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[ src$=\".svg\"]{ancho:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block}<\/style>\t\t\t\t\t\t\t\t\t\t<br>\n<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"638\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/terminal-block-cover-for-AC-1024x638.jpg\" alt=\"\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/terminal-block-cover-for-AC-1024x638.jpg 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/terminal-block-cover-for-AC-300x187.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/terminal-block-cover-for-AC-768x479.jpg 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/terminal-block-cover-for-AC.jpg 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><br>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<br>\n\t\t\t\t\t\t\t\t\t\t\t \t\t<br>\n<img loading=\"lazy\" decoding=\"async\" width=\"460\" height=\"322\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/AC-wall-mount-indoor-unit-connection.png\" alt=\"\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/AC-wall-mount-indoor-unit-connection.png 460w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/06\/AC-wall-mount-indoor-unit-connection-300x210.png 300w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><br>","protected":false},"excerpt":{"rendered":"<p>La cl\u00e1usula 8.1.1 menciona que la sonda de prueba debe usarse cuando el aparato est\u00e9 bajo &#8220;uso normal&#8221;, mientras que la cl\u00e1usula 8.1.5 se eval\u00faa antes de la instalaci\u00f3n. Productos como estos, que se entregan en varias partes, generalmente requieren instalaci\u00f3n in situ. &#8220;Vivo y nbsp;partes y nbsp;de y nbsp;empotrados y nbsp;electrodom\u00e9sticos, y nbsp;fijos y&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[10],"tags":[74,103,69,147,70],"class_list":["post-47","post","type-post","status-publish","format-standard","hentry","category-protection-against-access-to-live-parts","tag-insulation-applied-to-live-parts-to-provide-basic-protection-against-electric-shock","tag-part-that-can-be-removed-or-opened-without-the-aid-of-a-tool-part-that-is-removed-or-opened-in-accordance-with-the-instructions-for-use-even-if-a-tool-is-needed-for-removal-or-part-that-does-not-fu","tag-external-flexible-cord-between-two-parts-of-an-appliance-provided-as-part-of-a-complete-appliance-for-purposes-other-than-connection-to-the-supply-mains","tag-protection-against-electric-shock","tag-flexible-cord-for-supply-purposes-that-is-fixed-to-the-appliance"],"translation":{"provider":"WPGlobus","version":"3.0.1","language":"es","enabled_languages":["en","es","ar","de","ja","fr","ru","th","nl","it","fa","ko","pt","hi","ro","tr","vi","id","zu"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"nl":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"fa":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"ro":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"zu":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/posts\/47","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/comments?post=47"}],"version-history":[{"count":40,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/posts\/47\/revisions"}],"predecessor-version":[{"id":1672,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/posts\/47\/revisions\/1672"}],"wp:attachment":[{"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/media?parent=47"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/categories?post=47"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gezhi-tech.com\/es\/wp-json\/wp\/v2\/tags?post=47"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}