IEC 60335-1 Interpretation
  • clause 3

    Clause 3 – How to understand the definition of “stationary appliance”

    Byforest October 13, 2024October 13, 2024

    stationary appliance: fixed appliance or an appliance which is not a portable appliance. Stationary appliance includes fixed appliance and not a portable appliance. The characteristic of a stationary appliance is that once it is put into use, it will be placed in a fixed position. At the same time, the position of the appliances will…

    Read More Clause 3 – How to understand the definition of “stationary appliance”Continue

  • clause 3

    Clause 3 – How to understand the definition of “safety isolating transformer”

    Byforest October 13, 2024October 13, 2024

    hand-held appliance: portable appliance intended to held in the hand during normal use. Hair dryers, electric irons, hand-held vacuum cleaners, etc. are typical examples of hand-held appliances.

    Read More Clause 3 – How to understand the definition of “safety isolating transformer”Continue

  • clause 3

    Clause 3 – How to understand the definition of “portable appliance”

    Byforest October 13, 2024October 13, 2024

    portable appliance: appliance that is intended to be moved while in operation or an appliance, other than a fixed appliance, having a mass less than 18 kg. This item is relatively easy to understand. Products that are less than 18kg are relatively light, so they are easy to move during operation, including humidifiers, fans, air…

    Read More Clause 3 – How to understand the definition of “portable appliance”Continue

  • clause 3

    Clause 3 – How to understand the definition of “protective extra-low voltage circuit”

    Byforest September 7, 2024October 13, 2024

    protective extra-low voltage circuitportable appliance => portable appliance: earthed circuit operating at safety extra-low voltage which is separated from other circuits by basic insulation and protective screening, double insulation or reinforced insulationNOTE 1 Protective screening is the separation of circuits from live parts by means of an earthed screen.NOTE 2 A protective extra-low voltage circuitportable appliance => portable appliance…

    Read More Clause 3 – How to understand the definition of “protective extra-low voltage circuit”Continue

  • clause 3

    بند 3 – نحوه درک تعریف “ترانسفورماتور ایزوله ایمنی”

    Byforest September 5, 2024September 7, 2024

    ترانسفورماتور ذکر شده در اینجا برای تامین برق دستگاه ها یا مدارها استفاده می شود. بیشتر ترانسفورماتورهای رایج برق مدارها را تامین می کنند و تعداد کمی هم برق وسایل برقی را تامین می کنند. نکته کلیدی در اینجا، معیارهای جداسازی سیم‌پیچ ورودی و سیم‌پیچ خروجی است که باید از نوع عایق دوگانه یا عایق…

    Read More بند 3 – نحوه درک تعریف “ترانسفورماتور ایزوله ایمنی”Continue

  • clause 3

    Clause 3 – How to understand the definition of “safety extra-low voltage”

    Byforest September 5, 2024September 7, 2024

    safety extra-low voltage: voltage not exceeding 42 V between conductors and between conductors and earth, the no-load voltage not exceeding 50 V When safety extra-low voltage is obtained from the supply mains, it is to be through a safety isolating transformer or a convertor with separate windings, the insulation of which complies with double insulation…

    Read More Clause 3 – How to understand the definition of “safety extra-low voltage”Continue

  • clause 3

    بند 3 – نحوه درک تعریف “ولتاژ فوق العاده کم”

    Byforest September 4, 2024September 4, 2024

    ولتاژ بسیار کم: ولتاژی که از منبعی در دستگاه تامین می شود که از 50 ولت بین هادی ها و بین هادی ها و زمین زمانی که دستگاه با ولتاژ نامی تغذیه می شود تجاوز نمی کند ولتاژ خروجی باتری های آلکالاین خانگی معمولی، ولتاژ کاری مدار ولتاژ پایین بعد از ترانسفورماتور یا مدار پایین…

    Read More بند 3 – نحوه درک تعریف “ولتاژ فوق العاده کم”Continue

  • clause 3

    بند 3 – نحوه درک تعریف “فاصله خزش”

    Byforest September 1, 2024September 4, 2024

    فاصله خزش: کوتاهترین فاصله در امتداد سطح عایق بین دو قسمت رسانا یا بین یک قسمت رسانا و سطح قابل دسترسی. تعریف فاصله خزش از استاندارد IEC 60664-1:2020 می آید. از آنجایی که باید فاصله خزش را توضیح دهیم، باید تصاویر شکل 4 تا شکل 14 را در استاندارد IEC 60664-1:2020 نشان دهیم. در اینجا،…

    Read More بند 3 – نحوه درک تعریف “فاصله خزش”Continue

  • clause 3

    بند 3 – نحوه درک تعریف “ترخیص”

    Byforest August 27, 2024September 1, 2024

    ترخیص: کمترین فاصله در هوا بین دو قسمت رسانا یا بین یک قسمت رسانا وسطح قابل دسترسی. ترخیص یک مفهوم بسیار مهم است. برای درک پاکسازی، باید دوباره بگوییم که هیچ ماده ای کاملاً عایق نیست و هوا نیز می تواند جریان الکتریکی را هدایت کند. هنگامی که ولتاژ بسیار بالا باشد، جریان از طریق…

    Read More بند 3 – نحوه درک تعریف “ترخیص”Continue

Page navigation

Previous PagePrevious 1 2 3 4 5 6 … 11 Next PageNext

© copyright 2025 IEC 60335-1 Interpretation wangang

You cannot copy content of this page

  • About me
  • Blog
  • Shop
  • Cart
  • Checkout
  • My account
  • Persian
    • English
    • Spanish
    • Arabic
    • German
    • Japanese
    • French
    • Russian
    • Thai
    • Dutch
    • Italian
    • Korean
    • Portuguese
    • Hindi
    • Romanian
    • Turkish
    • Vietnamese
    • Indonesian
    • South African Zulu
Search