{"id":424,"date":"2024-08-10T10:55:22","date_gmt":"2024-08-10T08:55:22","guid":{"rendered":"https:\/\/gezhi-tech.com\/?p=424"},"modified":"2025-09-27T17:50:24","modified_gmt":"2025-09-27T15:50:24","slug":"clause-3-how-to-understand-the-definition-of-protective-impedance","status":"publish","type":"post","link":"https:\/\/gezhi-tech.com\/fr\/clause-3-how-to-understand-the-definition-of-protective-impedance\/","title":{"rendered":"Clause 3 \u2013 Comment comprendre la d\u00e9finition de \u00ab imp\u00e9dance de protection \u00bb"},"content":{"rendered":"imp\u00e9dance de protection\u00a0: imp\u00e9dance connect\u00e9e entre les parties actives et les parties conductrices accessibles des constructions de classe II de sorte que le courant, en utilisation normale et dans des conditions probables de d\u00e9faut dans l&#8217;appareil, soit limit\u00e9 \u00e0 une valeur s\u00fbre.<br>\n<br>\nCas 1 :<br>Le premier cas concerne g\u00e9n\u00e9ralement certaines situations n\u00e9cessitant une alimentation basse tension, telles que les produits aliment\u00e9s par un adaptateur. La tension de sortie de l&#8217;adaptateur est DC12V, DC24V ou DC5V. Ces parties basse tension peuvent g\u00e9n\u00e9ralement \u00eatre touch\u00e9es par les utilisateurs car la partie basse tension continue est obtenue par transformation du transformateur et redressement du courant du redresseur. Par cons\u00e9quent, il est n\u00e9cessaire de s\u2019assurer que la partie haute tension et la partie tension sont efficacement isol\u00e9es. Sur notre carte d&#8217;alimentation \u00e0 d\u00e9coupage commune, lors du test de conduction CEM, les interf\u00e9rences g\u00e9n\u00e9r\u00e9es par le primaire du transformateur traversent la capacit\u00e9 parasite entre le primaire et le secondaire, ce qui produira des interf\u00e9rences conduites de 150\u00a0000 \u00e0 30 MHz et atteindra le secondaire. Ici, nous utilisons des condensateurs Y pour faire revenir le signal d&#8217;interf\u00e9rence \u00e0 la source d&#8217;alimentation, formant une boucle pour compenser l&#8217;interf\u00e9rence, sinon le test de conduction \u00e9chouera. Le condensateur Y forme ici une imp\u00e9dance de protection. Les deux condensateurs Y s\u00e9lectionn\u00e9s dans l&#8217;encadr\u00e9 rouge de la figure ci-dessous sont l&#8217;imp\u00e9dance de protection.<br>\n<figure class=\"wp-block-image size-full\"><br>\n<img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"363\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/protective-impedance-in-switch-power-supply.jpg\" alt=\"\" class=\"wp-image-425\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/protective-impedance-in-switch-power-supply.jpg 760w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/protective-impedance-in-switch-power-supply-300x143.jpg 300w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><br>\n<\/figure><br>\nLes deux imp\u00e9dances de protection sont connect\u00e9es entre l&#8217;enroulement primaire et l&#8217;enroulement secondaire du transformateur T2\u00a0; la ligne pointill\u00e9e dans la figure ci-dessous indique la s\u00e9paration de la partie tension de fonctionnement 220-240 V et de la partie basse tension de fonctionnement (SELV).<br>\n<figure class=\"wp-block-image size-full is-resized\"><br>\n<img loading=\"lazy\" decoding=\"async\" width=\"373\" height=\"245\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/circuit-diagram-for-switch-power-supply.png\" alt=\"\" class=\"wp-image-426\" style=\"width:776px;height:auto\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/circuit-diagram-for-switch-power-supply.png 373w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/circuit-diagram-for-switch-power-supply-300x197.png 300w\" sizes=\"auto, (max-width: 373px) 100vw, 373px\" \/><br>\n<\/figure><br>\nCas 2\u00a0: Imp\u00e9dance de protection utilis\u00e9e sur le g\u00e9n\u00e9rateur d&#8217;ions n\u00e9gatifs. Comme le montre la figure de gauche ci-dessous, la ligne blanche correspond \u00e0 l&#8217;extr\u00e9mit\u00e9 de sortie haute tension et les deux autres lignes sont les lignes d&#8217;entr\u00e9e d&#8217;alimentation.<br>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\"><div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><br>\n<img loading=\"lazy\" decoding=\"async\" width=\"290\" height=\"476\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/220V-Negative-Ion-Generator-for-Air-Purifier-Accessories-Parts.png\" alt=\"\" class=\"wp-image-427\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/220V-Negative-Ion-Generator-for-Air-Purifier-Accessories-Parts.png 290w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/220V-Negative-Ion-Generator-for-Air-Purifier-Accessories-Parts-183x300.png 183w\" sizes=\"auto, (max-width: 290px) 100vw, 290px\" \/><br>\n<\/figure><\/div><div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><br>\n<img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"675\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator.jpg\" alt=\"\" class=\"wp-image-428\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator.jpg 916w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-300x221.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-768x566.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><br>\n<\/figure><\/div><\/div><br>\nLa figure ci-dessous est le sch\u00e9ma de circuit du g\u00e9n\u00e9rateur d&#8217;ions n\u00e9gatifs. Les deux r\u00e9sistances s\u00e9lectionn\u00e9es par le rectangle rouge sont des imp\u00e9dances de protection typiques.<br>\n<figure class=\"wp-block-image size-large\"><br>\n<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"403\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram-1024x403.png\" alt=\"\" class=\"wp-image-429\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram-1024x403.png 1024w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram-300x118.png 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram-768x302.png 768w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram-1536x604.png 1536w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/Negative-ion-generator-circuit-diagram.png 1954w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><br>\n<\/figure><br>\nDans l&#8217;image ci-dessous, les imp\u00e9dances de protection CY1 et CY2 sont-elles ?<br>\n<figure class=\"wp-block-image is-resized\"><br>\n<img decoding=\"async\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2024\/08\/is-it-a-protective-impedance.png\" alt=\"\" style=\"width:716px;height:auto\"\/><br>\n<\/figure><br>\nD&#8217;apr\u00e8s la d\u00e9finition de la norme, l&#8217;imp\u00e9dance de protection est utilis\u00e9e dans les constructions de classe II, o\u00f9 il y a une mise \u00e0 la terre. Si la mise \u00e0 la terre est ici d\u00e9finie comme mise \u00e0 la terre de protection, alors \u00e9videmment, CY1 et CY2 ne peuvent pas \u00eatre d\u00e9finis comme imp\u00e9dance de protection, car l&#8217;imp\u00e9dance de protection est utilis\u00e9e dans la construction de classe II, et ici c&#8217;est la construction de classe I. Si la mise \u00e0 la terre et nbsp;ici sont d\u00e9finies comme une mise \u00e0 la terre fonctionnelle, alors il y a deux probl\u00e8mes. Premi\u00e8rement, il s&#8217;agit d&#8217;une structure de classe I, alors CY1 et CY2 ne peuvent pas \u00eatre d\u00e9finis comme imp\u00e9dance de protection. Deuxi\u00e8mement, s&#8217;il s&#8217;agit d&#8217;une structure de classe II, CY1 et CY2 peuvent \u00eatre d\u00e9finis comme imp\u00e9dance de protection, et les exigences pertinentes en mati\u00e8re d&#8217;imp\u00e9dance de protection doivent alors \u00eatre respect\u00e9es. Mon opinion personnelle est que CY1 et CY2 ne sont pas des imp\u00e9dances de protection, et nous pouvons directement les consid\u00e9rer comme une isolation de base. Au final, en d\u2019autres termes, la conception pr\u00e9sent\u00e9e dans le sch\u00e9ma de circuit n\u2019est pas accept\u00e9e par la norme\u00a0? et nbsp;<br>\n<br>\nS&#8217;il s&#8217;agit d&#8217;imp\u00e9dances de protection, alors celles-ci doivent \u00eatre conformes \u00e0 la clause 22.42 &#8211; &#8220;L&#8217;imp\u00e9dance de protection doit \u00eatre compos\u00e9e d&#8217;au moins deux composants distincts.&#8221;.<br>","protected":false},"excerpt":{"rendered":"<p>imp\u00e9dance de protection\u00a0: imp\u00e9dance connect\u00e9e entre les parties actives et les parties conductrices accessibles des constructions de classe II de sorte que le courant, en utilisation normale et dans des conditions probables de d\u00e9faut dans l&#8217;appareil, soit limit\u00e9 \u00e0 une valeur s\u00fbre. Cas 1 :Le premier cas concerne g\u00e9n\u00e9ralement certaines situations n\u00e9cessitant une alimentation basse&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-424","post","type-post","status-publish","format-standard","hentry","category-terms-and-definitions"],"translation":{"provider":"WPGlobus","version":"3.0.1","language":"fr","enabled_languages":["en","es","ar","de","ja","fr","ru","th","nl","it","fa","ko","pt","hi","ro","tr","vi","id","zu"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":true,"content":true,"excerpt":false},"ar":{"title":true,"content":true,"excerpt":false},"de":{"title":true,"content":true,"excerpt":false},"ja":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false},"ru":{"title":true,"content":true,"excerpt":false},"th":{"title":true,"content":true,"excerpt":false},"nl":{"title":true,"content":true,"excerpt":false},"it":{"title":true,"content":true,"excerpt":false},"fa":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"pt":{"title":true,"content":true,"excerpt":false},"hi":{"title":true,"content":true,"excerpt":false},"ro":{"title":true,"content":true,"excerpt":false},"tr":{"title":true,"content":true,"excerpt":false},"vi":{"title":true,"content":true,"excerpt":false},"id":{"title":true,"content":true,"excerpt":false},"zu":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/posts\/424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/comments?post=424"}],"version-history":[{"count":78,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/posts\/424\/revisions"}],"predecessor-version":[{"id":2085,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/posts\/424\/revisions\/2085"}],"wp:attachment":[{"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/media?parent=424"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/categories?post=424"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gezhi-tech.com\/fr\/wp-json\/wp\/v2\/tags?post=424"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}