{"id":2727,"date":"2025-01-27T07:35:43","date_gmt":"2025-01-27T06:35:43","guid":{"rendered":"https:\/\/gezhi-tech.com\/?p=2727"},"modified":"2025-10-05T09:04:18","modified_gmt":"2025-10-05T07:04:18","slug":"clause-3-how-to-understand-the-definition-of-protective-device","status":"publish","type":"post","link":"https:\/\/gezhi-tech.com\/pt\/clause-3-how-to-understand-the-definition-of-protective-device\/","title":{"rendered":"Clause 3 \u2013 How to understand the definition of \u201cprotective device\u201d"},"content":{"rendered":"<p><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-protective-device\/\" target=\"_blank\"> <strong>protective device<\/strong><\/a>: device, the operation of which prevents a hazardous situation under abnormal operation conditions<\/p>\n\n\n\n<p>The standard emphasizes &#8220;abnormal operation&#8221; here. Only devices that operate under &#8220;abnormal operation&#8221; conditions can be defined as protective devices. Therefore, there are many types of protective devices, including overheating protection devices, overcurrent protection devices, and overpressure protection devices. <br>Overheating protection devices include the <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-thermal-link\/\" target=\"_blank\"> <strong>thermal link<\/strong><\/a>, non-<a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-self-resetting-thermal-cut-out\/\" target=\"_blank\"> <strong>self-resetting thermal cut-out<\/strong><\/a>, self-resetting thermal cut-out, thermal cut-out, etc. mentioned earlier, but <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-thermostat\/\" target=\"_blank\"> <strong>thermostat<\/strong><\/a> and <a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-temperature-limiter\/\" target=\"_blank\"> <strong>temperature limiter<\/strong><\/a> are not protective devices. <br>The typical overcurrent protection device is the current fuse. There are many types of general current fuses. We will not introduce them here. Readers can go to Google by themselves. <br>Overpressure protection devices include water pressure protection devices, air pressure protection devices, etc. <br>In addition, there are water level switches, interlocking switches or devices that prevent a hazardous situation, three-phase electrical phase sequence protection devices, Air Circuit Breaker(ACB), leakage current protectors, etc., as well as intentionally weak parts defined by the standard. We can search for the word &#8220;protective device&#8221; in the standard to see what requirement are given for the &#8220;protective device&#8221; standard. This way we can understand the definition in reverse. This method can also be used to understand other definitions.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"524\" height=\"384\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/current-fuse-0.5A.jpg\" alt=\"\" class=\"wp-image-2732\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/current-fuse-0.5A.jpg 524w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/current-fuse-0.5A-300x220.jpg 300w\" sizes=\"auto, (max-width: 524px) 100vw, 524px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/High-Voltage-Low-Current-EV-Fuse-600-Volt-20-Amp-ATM20.jpg\" alt=\"\" class=\"wp-image-2729\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/High-Voltage-Low-Current-EV-Fuse-600-Volt-20-Amp-ATM20.jpg 600w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/High-Voltage-Low-Current-EV-Fuse-600-Volt-20-Amp-ATM20-300x300.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/High-Voltage-Low-Current-EV-Fuse-600-Volt-20-Amp-ATM20-150x150.jpg 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">High Voltage Low Current EV Fuse<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"198\" height=\"255\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/big-current-fuse.jpg\" alt=\"\" class=\"wp-image-2730\" style=\"width:127px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"772\" height=\"544\" src=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/surface-mounted-current-fuse.jpg\" alt=\"\" class=\"wp-image-2733\" srcset=\"https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/surface-mounted-current-fuse.jpg 772w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/surface-mounted-current-fuse-300x211.jpg 300w, https:\/\/gezhi-tech.com\/wp-content\/uploads\/2025\/01\/surface-mounted-current-fuse-768x541.jpg 768w\" sizes=\"auto, (max-width: 772px) 100vw, 772px\" \/><figcaption class=\"wp-element-caption\">surface mounted current fuse<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p><a href=\"\/index.php\/clause-3-how-to-understand-the-definition-of-protective-device\/\" target=\"_blank\"> <strong>protective device<\/strong><\/a>: device, the operation of which prevents a hazardous situation under abnormal operation conditions The standard emphasizes &#8220;abnormal operation&#8221; here. Only devices that operate under &#8220;abnormal operation&#8221; conditions can be defined as protective devices. Therefore, there are many types of protective devices, including overheating protection devices, overcurrent protection devices, and overpressure protection devices. Overheating&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[5],"tags":[121,118,119,117,116,120],"class_list":["post-2727","post","type-post","status-publish","format-standard","hentry","category-terms-and-definitions","tag-part-intended-to-rupture-under-conditions-of-abnormal-operation-to-prevent-the-occurrence-of-a-condition-which-could-impair-compliance-with-this-standard","tag-thermal-cut-out-that-requires-a-manual-operation-for-resetting-or-replacement-of-a-part-in-order-to-restore-the-current","tag-device-the-operation-of-which-prevents-a-hazardous-situation-under-abnormal-operation-conditions","tag-thermal-cut-out-that-automatically-restores-the-current-after-the-relevant-part-of-the-appliance-has-cooled-down-sufficiently","tag-device-which-during-abnormal-operation-limits-the-temperature-of-the-controlled-part-by-automatically-opening-the-circuit-or-by-reducing-the-current-and-is-constructed-so-that-its-setting-cannot-be","tag-thermal-cut-out-which-operates-only-once-and-requires-partial-or-complete-replacement"],"translation":{"provider":"WPGlobus","version":"3.0.1","language":"pt","enabled_languages":["en","es","ar","de","ja","fr","ru","th","nl","it","fa","ko","pt","hi","ro","tr","vi","id","zu"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"nl":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"fa":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"ro":{"title":false,"content":false,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"zu":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/posts\/2727","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/comments?post=2727"}],"version-history":[{"count":3,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/posts\/2727\/revisions"}],"predecessor-version":[{"id":2835,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/posts\/2727\/revisions\/2835"}],"wp:attachment":[{"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/media?parent=2727"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/categories?post=2727"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gezhi-tech.com\/pt\/wp-json\/wp\/v2\/tags?post=2727"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}