functional insulation as well as other insulation exists on circuit boards. Typically, the surface environment of a circuit board is determined to be either Pollution degree 3 or pollution degree 2.If the circuit board is mounted in an electrical box and sealed with a solid sealant, the sealing will look as follows: What should be…
We know that clause 29.3.2 and clause 21.2 are two separate clauses and they are not very much related, which means that the product being assessed needs to fulfill both clauses if applicable.A reinforced insulation system consisting of three separate layers of insulating material or what could be considered a double insulation system, Each layer…
دستگاه کلاس III: دستگاهی که در آن حفاظت در برابر شوک الکتریکی متکی به تامین برق با ولتاژ بسیار پایین ایمنی است و در آن ولتاژهای بالاتر از ولتاژ بسیار پایین ایمنی تولید نمی شود.نکته ممکن است علاوه بر عرضه در SELV، عایق اولیه نیز مورد نیاز باشد. به 8.1.4. برای درک این موضوع، ابتدا…
کلاس 0: دستگاهی که در آن حفاظت در برابر شوک الکتریکی فقط به عایق اولیه متکی است، هیچ وسیله ای برای اتصال قطعات رسانا در دسترس، در صورت وجود، به هادی محافظ در سیم کشی ثابت تاسیسات، اتکا در صورت وجود ندارد. خرابی عایق اولیه که روی محیط قرار می گیرد.یادداشت لوازم خانگی کلاس 0…
ساخت و ساز کلاس III: بخشی از دستگاهی که حفاظت در برابر شوک الکتریکی برای آن به ولتاژ بسیار پایین ایمنی متکی است و در آن ولتاژهای بالاتر از ولتاژ بسیار پایین ایمنی تولید نمی شود.توجه داشته باشید ممکن است علاوه بر عرضه در SELV، عایق اولیه نیز مورد نیاز باشد. به 8.1.4.تذکر 2 اگر…
ترخیص: کمترین فاصله در هوا بین دو قسمت رسانا یا بین یک قسمت رسانا وسطح قابل دسترسی. ترخیص یک مفهوم بسیار مهم است. برای درک پاکسازی، باید دوباره بگوییم که هیچ ماده ای کاملاً عایق نیست و هوا نیز می تواند جریان الکتریکی را هدایت کند. هنگامی که ولتاژ بسیار بالا باشد، جریان از طریق…