Clause 3 – How to understand the definition of “tool”

tool: screwdriver, coin or any other object that may be used to operate a screw or similar fixing means.

I’d like to explain the intent of the standard, which defines a separate tool, in order to distinguish between operations that use a tool and those that do not. For example, if a tool is used to remove a part of an appliance, the standard considers this to be a conscious action by the user; conversely, if the part can be removed without a tool, the operation is an unconscious action by the user. Then for conscious behavior and unconscious behavior, the standard for the results of the behavior to do the protection requirements, is not the same.
Is a key a tool? The author here believes that the key can be defined as a tool, because in the refrigerator product IEC 60335-2-24, there is a special requirement for the refrigerator with a key to open, and inferred from the principle of this requirement, the key can be considered as a tool. In addition, keys are defined as tools in the standard IEC 61010-1.

Similar Posts

  • Clause 3 – How to understand the definition of “detachable power supply part”

    detachable power supply part: part of the appliance the output of which is intended to be detachable from the class III construction part of the appliance.Note 1 to entry: Means of detachment are a flexible cord and connector or an appliance outlet fitted to the detachable power supply part. This actually defines a detachable adapter….

  • Clause 3 – How to understand the definition of “detachable part”

    detachable part: part that can be removed or opened without the aid of a tool, a part that is removed or opened in accordance with the instructions for use, even if a tool is needed for removal, or a part that does not fulfil the test of 22.11.NOTE 1 If for installation purposes a part…

  • 第3項 「定格電圧範囲」の定義の見方

    定格電圧範囲:メーカーによって家電製品に割り当てられた電圧範囲。下限値と上限値で表されます。 この定義は、の定義を拡張したものです 定格電圧定格電圧 定格電圧、ただし、定格電圧が定義されていることはほとんどありません。 例えば、ヨーロッパの全EU加盟国市場を対象市場として設計された製品の場合、ほとんどのEU加盟国の商用電圧はAC 230Vですが、別途規定があればAC 240Vである国もあります定格電圧がAC230VまたはAC240Vの場合、本製品は国の定格電圧と異なる商用電圧では使用できません。このような状況を考慮し、AC220VとAC230V、AC240VをカバーするAC220~240Vの範囲で定格電圧を規定し、これら3つの商用電圧の国でも対応製品を使用できるようにしました。ここでは、AC220-240V または 220-240V~ がより一般的な形式です。 220 ~ 230V ~、380V ~ 415V ~、または 100 ~ 240V ~ (この状況のほとんどは、アダプターの定格入力電圧で電力供給されるアダプターの使用時に発生します) などもあります。製品の定格電圧は範囲が設定されているため、その電圧範囲における安全要件を規格に従って評価する必要があります。 For example, a product designed for the target market for the whole of Europe’s all EU member states market, most of the EU member states of the utility voltage is AC 230V,…

  • Clause 3 – How to understand the definition of “protective electronic circuit”

    protective electronic circuit: electronic circuit that prevents a hazardous situation under abnormal operating conditions.NOTE Parts of the circuit may also be used for functional purposes. With the advancement of technology, more and more electronic circuits are being used in household electrical products, and these electronic circuits are usually integrated on PCBs. They use microprocessor chips…

  • 第3項 「特別低圧」の定義の見方

    特別低電圧:機器内の電源から供給される電圧であって、機器が定格電圧で供給されている場合に、導体間および導体とアース間が50Vを超えない電圧 EU 低電圧指令の定義によれば、低電圧の範囲は AC で 50 ~ 1000V、DC で 75 ~ 1500V です。ちなみに、ほとんどの国ではこの電圧値に応じて高電圧と低電圧を分けています。したがって、範囲の上限を超える電圧は高電圧となり、範囲の下限を下回る電圧は超低電圧となります。この規格における定義では、DC と AC は区別されません。ここで注意していただきたいのは、電圧名は電圧値に応じて定義されているだけであり、低電圧回路の特定の部分を定義するものではありません。電圧は相対的なものであるため、電圧を測定する場合、電圧は両端間で測定する必要があります。つまり、電圧には基準点が必要であるため、規格ではワイヤ間およびワイヤとアース間の電圧について言及しています。 一般家庭用アルカリ電池の出力電圧、一般家庭用電化製品の制御基板上の変圧器以降の低圧回路やRC降圧回路の動作電圧など、いずれも特別低電圧と定義できるもの. 下図のようにR1とC1で降圧機能が完成しますので、R1とC1以降の回路は特別低圧回路と定義できます。

  • 第 3 項 – 「安全絶縁変圧器」の定義の理解方法

    安全絶縁変圧器:安全超低電圧で機器または回路に供給することを目的とした、少なくとも二重絶縁または強化絶縁と同等の絶縁によって入力巻線が出力巻線から電気的に分離された変圧器 ここで言う変圧器は、機器や回路に電力を供給するために使用されます。最も一般的な変圧器は回路に電力を供給し、いくつかの変圧器は電化製品に電力を供給します。ここで重要となるのは入力巻線と出力巻線の絶縁対策であり、二重絶縁もしくは強化絶縁タイプ、または同等の絶縁が必要となります。この要件は、一次巻線と二次巻線が十分な絶縁を有することを保証することです。絶縁が十分であれば、変圧器の一次巻線と二次巻線間の絶縁は比較的安全です。二重の保護予防策。 スイッチの電源基板に使用される最初の種類のトランス。このタイプの変圧器は、同じ磁気コア上に一次巻線と二次巻線を重ね合わせます。したがって、一次側と二次側の間の沿面距離と電気的空間を確保するために、巻線を上下の端面に配置することはできません。以下の図に示すように、巻線は上下の端面から一定の距離にある必要があります。 安全絶縁トランスの全体図 安全絶縁トランスの全体図 The other is a drawer-type linear transformer, as shown below: