25.20 Do supply cord entering the metal enclosure need an additional layer of insulation at the vias?

25.20: The conductors of the supply cord for type Y attachment and type Z attachment shall be insulated from accessible metal parts by basic insulation for class 0 appliances, class 0I appliances and class I appliances, and by supplementary insulation for class II appliances. This insulation may be provided by the sheath of the supply cord or by other means.

This clause should be considered with clause 16.3, generally condition, all most countries employed supply cord with double insulation except those countries based on main power voltage less than 150V, such as Japan, America, Mexico etc.

double insulation of supply cord

I guess most people would think that the white insulation enclosure on the outside of supply cord should be the sheath or other means. But it is not. Here, the supply cord do need an additional sheath or other means, please pay attention, a sheath is only required when the supply cord passes directly through the accessible metal enclosure of the appliance, because the first sentence of clause 25.20 mentions the insulating sheath between accessible metal parts and the supply cord.

Why I could get such a conclusion? We could refer to clause 16.3, the following content:

A test voltage is applied between accessible metal parts and the supply cord which is wrapped with metal foil at the point where the supply cord is located in an inlet bushing and where, for appliances having a type X attachment, the supply cord is located in a cord guard or a cord anchorage with their clamping screws, if any, being tightened to two-thirds of the torque specified in Table 14. The test voltage is 1 250 V for class I appliances and 1 750 V for class II appliances.

Clause 16.3 requires that the supply cord be wrapped with a metal foil at the inlet before the electrical strength test. If there is no insulating sheath outside the power cord, the test will fail.

Combining the requirements of two different clause of the standard, we can infer the standard’s intent.

What type of sheath should be used? The standard does not require a sheath, other types are acceptable. The following photo show an acceptable structure.

The method shown in the image serves both as insulation and as a cable clamp.

In the image below, because the supply cord via is made of non-metallic plastic, clause 25.20 is not applicable.

Similar Posts

  • 第3項「二重絶縁」の定義の見方

    二重絶縁:基礎絶縁と補助絶縁を併用した絶縁方式 次の回路基板の画像にはアニメーション効果があります。点線の右側は動作電圧 220 ~ 240V のアクセス不可能な部分であり、点線の左側は最大動作電圧 24V のアクセス可能な部分です (点線の位置の構造が正常であると仮定します)。ラインは二重絶縁または強化絶縁の要件を満たしています)。効果的な絶縁を確保するために、一般的に、点線の右側のワイヤ (赤と青の内部ワイヤ) は、左側の比較的細い内部ワイヤに触れることはできません。右側のワイヤのワイヤ シースは基礎絶縁です。これは、ワイヤ シースが充電部と直接接触しており、充電部を保護する最初の層であるためです。左側の電線の電線シースは補助絶縁としてのみ定義できますが、第 29.3 項の補助絶縁の要件を満たしているかどうかは、第 29.3 項を導入する際に分析されます。 ここで、左側の電線の電線被覆を基礎絶縁、右側の電線の電線被覆を補助絶縁とすることはできないことに注意してください。 As shown in the following two pictures(fan), the internal lead wires sheath in the left picture is basic insulation, and the bottom plate of the outer casing is additional insulation. The following circuit board picture has an…

  • 第3項 「タイプZアタッチメント」の定義の見方

    タイプ Z アタッチメント: 製造元、そのサービス代理店、または同様の資格を持つ担当者が交換を行うための電源コードの取り付け方法。 一部の製品の電源コードは製品と一体成型されており、一般的な工具では取り外すことができません。または、一部の電化製品の電源コードは、接続後に熱硬化性材料によって電化製品にキャストされます。これらの同様の構造では、電源コードの交換作業を完了するには、電源コードに接続されている材料を破壊する必要があります。例:図のように水中ポンプのシェルに電源コードをエポキシ樹脂で流し込んでいます。電源コードを交換する場合は、注型エポキシ樹脂を破壊する必要があります。 ウォーターポンプ内部図

  • A question about whether the second part of clause 21.2 needs to be tested.

    We know that clause 29.3.2 and clause 21.2 are two separate clauses and they are not very much related, which means that the product being assessed needs to fulfill both clauses if applicable.A reinforced insulation system consisting of three separate layers of insulating material or what could be considered a double insulation system, Each layer…

  • 第 3 項 – 「タイプ Y アタッチメント」の定義の理解方法

    タイプ Y アタッチメント: 製造元、そのサービス代理店、または同様の資格を持つ担当者が交換を行うための電源コードの取り付け方法。 次の 2 つの写真に示すように、アプライアンスの底部にあるカバーを取り外すと、コード クランプと内部電源コード コネクタが見えます。底部カバーの取り外しは比較的簡単ですが、電源コードが同様のニップルコネクタに接続されているか、機械的に固定されている場合は、電源コードを再接続するために専門の工具や破壊が必要となり、電源コードの交換が困難になります。この構造をタイプ Y アタッチメントとして定義する方が合理的です。 As shown in the following two pictures, after removing the cover at the bottom of the appliance, you can see the cord clamp and the internal supply cord connector. Removing the bottom cover is relatively easy, but if the power cord is connected with…

  • 第3項 「タイプX、タイプY、タイプZのアタッチメント」の定義の見方

    接続のタイプはアプライアンスのメーカーによって定義されます。一般に、これをタイプ X として定義することはまれです。これは、メーカーに不必要なリスクをもたらすことになるためです。一般にタイプ Y として定義されます。もちろん、電源コードが鋳造されている場合は、一般にタイプ Z として定義されます。次の図は、3 種類のアタッチメントの接続図を示しています。 タイプ X アタッチメント: 電源コードの接続は、アプライアンス内の特別に用意されたスペースで完了します。したがって、電源コードを交換する際には、端子台と内部配線以外の部分には触れません。電源コードを固定するネジは、通常の十字ネジまたは皿ネジです。電源コードの交換は管理可能な範囲内で行ってください。一般ユーザーが交換する電源コードは比較的シンプルで操作しやすいです。 タイプ Z アタッチメント、3.2.6 の説明と例を参照。 type Z attachment, see the explanation and examples in 3.2.6.

  • 第 3 項 – 「クラス I アプライアンス」の定義の理解方法

    クラス I 機器: 感電に対する保護が基礎絶縁のみに依存するのではなく、導電性のアクセス可能な部品がそのような方法で設備の固定配線内の保護接地線に接続されるという追加の安全予防措置が含まれる機器。基礎絶縁が破損した場合でも、導電性のアクセス可能な部分が通電状態になることはありません注: この規定には、電源コード内の保護接地導体が含まれます。 二重保護の概念から、感電に対する保護には 2 つの注意事項があります。 1つ目は基礎絶縁、2つ目は接地です。基本的な絶縁に欠陥がある場合(内部ワイヤシースの破断、またはモータの巻線とステータディスク間の絶縁欠陥など)、危険な電流が機器のエンクロージャやエンクロージャなどのアクセス可能な金属部分を通って流れます。ファンモーターの。したがって、金属部品が接地されている場合、電気は接地を通して迂回され、人体には流れません。これは、機器のアクセス可能な金属部品と外部の接地導体間の抵抗は、通常、人体に比べて非常に小さいためです。体。電気は抵抗の低い導電経路を通って流れます。つまり、電気は接地導体を通って外部の接地グリッドに希釈されます。ここで述べた設備の固定配線の保護接地線は、固定配線の保護接地線であり、単に家庭用コンセントの接地ソケットとして理解されます。電気はこのコンセントを通って大地に流れます。地球は無限の良導体です。地球がこれらの電荷を薄めている、あるいは私たちが地球の上に立っているので、地球と同じ電位にあることが理解できます。電位差がある場合にのみ電流が発生します。したがって、人体に電流が流れることはなく、危険はありません。名前が示すように、保護接地線は保護のために使用されます。これは前述したとおりです。漏電事故が発生した場合、漏洩電流が大地に流れる可能性があります。例:エアコンの室外機や電気バーベキューグリルなど、大型の金具を使用した器具は基本的にクラスⅠ器具として設計されていますが、一部の金具を使用したレンジフード製品については、アースが取られていないクラスⅡ器具として設計されている場合があります。 /*!エレメント – v3.23.0 – 2024 年 5 月 8 日 */ および lt;br / アースはどのようにして電気製品のユーザーを感電から保護しますか? 金属ケースを備えた機器(トースターなど)に、活線が金属ケースに接触する故障が発生した場合、金属ケースが接地されていないと、金属ケースが活線となり、接触した人は感電する可能性があります。 しかし、金属ケースがアースされているトースターで同じ故障が発生した場合、回路が短絡して大電流が流れ、回路ブレーカーが作動して危険な状態が解消されます。事件が生きてくることは一度もなかった。さらに、障害があることがわかり、電気技師に修理してもらうことができます。 人体の抵抗は乾燥状態では 100000 オームにも達しますが、濡れて傷ついた皮膚では 1000 オームにまで低下することがあります。 アース経路の抵抗は 1 オームに抑えられています。さて、故障が発生したり、電流の漏れが発生したりすると、接地されたシステムでは、この電流は接地導体、つまり接地から流れます。アースが提供されていないシステムでは、人が触れることで、障害電流や漏れ電流が流れる抵抗が最小になる可能性があります。 特殊なケースが 2 つあります 英国のプラグなどの最初のピンは通常 3 つのピンがあり、そのうちの 1 つは他の 2 つよりも長くなります。この最も長いピンはアースに使用されます。ただし、アースピンが非金属材料に置き換えられる場合もあります。この場合、機器には接地対策が施されていないため、製品をクラス I 機器として定義することはできません。さらに、ピンは依然として金属である可能性がありますが、内部にはアース接続がありません。同様に、アプライアンスをクラス I アプライアンスとして定義することはできません。 下の写真はこのプラグです。BSI プラグの金属製アース ピンをプラスチック製のピンに置き換えBSI プラグの金属製アース ピンをプラスチック製のピンに置き換え2 番目は、機器には接地対策が施されていますが、この接地対策は PCB…