Clause 3 – How to understand the definition of “room temperature”

room temperature: ambient temperature specified in the general conditions for the tests.
Note 1 to entry: The ambient temperature is specified in 5.7.

This item comes from standard IEC 60335-1:2020 edition 6.0. In commented version (CMV) of the official standard IEC 60335-1:2020 edition 6.0 allows the user to identify the changes made to the previous edition IEC 60335-1:2010 +AMD1:2013+AMD2:2016 CSV edition 5.2Experts’ comments are identified by a blue-background number. This item has comment “This term and definition was added to clarify what is intended when the term is used when applying the test specifications in the standard.” I think this comment gave us good explanation for this item.

Similar Posts

  • Clause 3 – How to understand the definition of “thermal cut-out”

    thermal-cut-out: device which during abnormal operation limits the temperature of the controlled part by automatically opening the circuit, or by reducing the current, and is constructed so that its setting cannot be altered by the user. There are three key provisions here. First, the thermal cut-out is a heat-sensing element, second, it can only be…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “แรงดันไฟฟ้า”

    แรงดันไฟฟ้าที่ผู้ผลิตกำหนดให้กับเครื่องใช้ไฟฟ้า:โดยทั่วไป แรงดันไฟฟ้านี้เป็นแรงดันไฟฟ้ามาตรฐานสำหรับประเทศของตลาดเป้าหมาย ณ เวลาที่ออกแบบผลิตภัณฑ์ เมื่อกำหนดตลาดเป้าหมายแล้ว ผู้ผลิตจำเป็นต้องออกแบบผลิตภัณฑ์ให้สอดคล้องกับความต้องการของตลาดเป้าหมาย ไม่สามารถออกแบบผลิตภัณฑ์ที่มีแรงดันไฟฟ้า AC100V (แรงดันไฟฟ้าขาเข้าของแหล่งจ่ายไฟ) โดยมีจุดประสงค์เพื่อใช้ในประเทศที่มีแรงดันไฟฟ้าหลักอยู่ที่ AC220V ในขณะเดียวกัน แรงดันไฟฟ้าหลักในประเทศส่วนใหญ่จะเป็นค่าที่กำหนดไว้ ดังนั้นค่าแรงดันไฟฟ้าที่กำหนดในที่นี้จึงเป็นค่าที่แยกจากกัน International Electrotechnical Commission นำเสนอข้อมูลรายการหน้าเว็บเกี่ยวกับปลั๊กและแรงดันไฟฟ้าหลักสำหรับทุกประเทศ: ในมาตรฐาน IEC 60335-1 การทดสอบทั้งหมดที่จำเป็นต้องจ่ายไฟให้กับผลิตภัณฑ์หรือผลิตภัณฑ์เพื่อให้อยู่ในสภาพการทำงานจะขึ้นอยู่กับแรงดันไฟฟ้าที่กำหนด หากเลือกแรงดันไฟฟ้าที่กำหนดไม่ถูกต้อง ต้องทำการทดสอบทั้งหมดซ้ำ ห้องปฏิบัติการจำเป็นต้องกำหนดแรงดันไฟฟ้าก่อนทำการทดสอบ https://iectest.iec.ch/world-plugsIEC 60335-1 ไม่ได้ระบุค่าหรือช่วงของแรงดันไฟฟ้าที่กำหนดที่ควรตั้งค่าแรงดันไฟฟ้าที่กำหนด แต่จริงๆ แล้วช่วงของแรงดันไฟฟ้าที่กำหนดให้ไว้เป็นข้อมูลอ้างอิงในย่อหน้าแรกของข้อ 1 ซึ่งไม่ เกิน 250 โวลต์สำหรับเครื่องใช้ไฟฟ้าแบบเฟสเดียว และ 480 โวลต์สำหรับเครื่องใช้ไฟฟ้าแบบสามเฟสและแหล่งจ่ายไฟประเภทอื่นๆ โดยทั่วไปแรงดันไฟฟ้าที่กำหนดจะต้องไม่เกินช่วงนี้ สิ่งสำคัญที่ควรทราบคือแต่ละประเทศเพิ่มส่วนเบี่ยงเบนของตนเองตามมาตรฐาน IEC 60335-1 และโดยทั่วไปแล้วการเบี่ยงเบนเหล่านี้จะเพิ่มข้อกำหนดแรงดันไฟฟ้าที่กำหนด ตัวอย่างเช่น 100V ในญี่ปุ่น 240V ในสหราชอาณาจักร และ 220V ในประเทศจีน มีการตัดสินใจ PDSH 2235 สำหรับเครื่องชาร์จแบตเตอรี่คลาส…

  • Clause 3 – How to understand the definition of “thermostat”

    thermostat: temperature-sensing device, the operating temperature of which may be either fixed or adjustable and which during normal operation keeps the temperature of the controlled part between certain limits by automatically opening and closing a circuit. The thermostat itself does not control the temperature, the thermostat senses the temperature and controls the temperature by switching…

  • Clause 3 – How to understand the definition of “protective electronic circuit”

    protective electronic circuit: electronic circuit that prevents a hazardous situation under abnormal operating conditions.NOTE Parts of the circuit may also be used for functional purposes. With the advancement of technology, more and more electronic circuits are being used in household electrical products, and these electronic circuits are usually integrated on PCBs. They use microprocessor chips…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “กระแสไฟฟ้าที่ได้รับการจัดอันดับ”

    หมายเหตุ หากไม่มีการกำหนดกระแสไฟฟ้าให้กับเครื่องใช้ไฟฟ้า กระแสไฟที่กำหนดจะเป็น– สำหรับเครื่องทำความร้อน กระแสไฟฟ้าคำนวณจากกำลังไฟเข้าที่กำหนดและแรงดันไฟฟ้าที่กำหนด– สำหรับเครื่องใช้ไฟฟ้าที่ทำงานด้วยมอเตอร์และเครื่องใช้ไฟฟ้าแบบรวม กระแสไฟฟ้าที่วัดได้เมื่อจ่ายเครื่องใช้ไฟฟ้าด้วยแรงดันไฟฟ้าที่กำหนดและทำงานภายใต้การทำงานปกติ สิ่งนี้สอดคล้องกับกำลังไฟฟ้าเข้าที่กำหนด และถูกกำหนดในลักษณะเดียวกับกำลังไฟฟ้าเข้าที่กำหนด หมายเหตุแรกของข้อนี้ เครื่องทำความร้อน เนื่องจากมีเพียงองค์ประกอบความร้อนไฟฟ้าเพื่อให้ความร้อนเท่านั้น องค์ประกอบความร้อนนี้โดยพื้นฐานแล้วจะมีโหลดความต้านทานเพียงอย่างเดียว ดังนั้นคุณจึงสามารถปฏิบัติตามวิธีการคำนวณทางคณิตศาสตร์ได้โดยตรง เนื่องจากกระแสจะเท่ากับกำลังไฟฟ้าเข้าที่หาร โดยแรงดันไฟฟ้าที่กำหนด (P = U/I) หมายเหตุประการที่สอง เนื่องจากผลิตภัณฑ์ไม่ใช่โหลดที่มีความต้านทานเพียงอย่างเดียว ดังนั้นตามสูตรการคำนวณ P = U/I จึงไม่ได้ให้ผลลัพธ์ที่ถูกต้อง มีเพียงการทดสอบเพื่อให้ได้ค่าปัจจุบันเท่านั้นโดยทั่วไปมีบ้างเครื่องใช้ไฟฟ้าที่ทำงานด้วยมอเตอร์ มีป้ายระบุพิกัดกระแสในป้ายพิกัด เช่น ตู้เย็น เครื่องปรับอากาศส่วนใหญ่จะมีทั้งกำลังไฟเข้าพิกัดและกระแสไฟพิกัดบนป้ายพิกัด ฉลากจัดอันดับสำหรับตู้เย็น ป้ายเรตติ้งเครื่องปรับอากาศ rating label for air conditioner

  • |

    If the PCB is sealed with solid sealant, how to determine the creepage distance and clearance?

    functional insulation as well as other insulation exists on circuit boards. Typically, the surface environment of a circuit board is determined to be either Pollution degree 3 or pollution degree 2.If the circuit board is mounted in an electrical box and sealed with a solid sealant, the sealing will look as follows: What should be…