Clause 3 – How to understand the definition of “self-resetting thermal cut-out”

self-resetting thermal cut-out: thermal cut-out that automatically restores the current after the relevant part of the appliance has cooled down sufficiently

In the definition there is a clear mention, when the temperature is cooled to a certain degree, in fact, its intention is to control the temperature is not too high, when the temperature is too high, the thermal cut-out opens the circuit or reduces the current, these two means will reduce the heat, when the heat is down, the temperature’s also down, the thermal cut-out will automatically restores the current.
A common type of self-resetting thermal cut-out is the thermal protector used in fan motors, as shown below.

Similar Posts

  • 第3項「定格入力」の定義の見方

    定格入力電力:メーカーによってアプライアンスに割り当てられた電源入力記入への注記 1: 機器に電源入力が割り当てられていない場合、加熱機器および複合機器の定格入力電力は、機器が定格電圧で供給され、通常の動作で動作したときに測定された電源入力です。 一般に、メーカーは、最大電力入力の条件下で定格電圧で動作する製品によって生成される入力電力に基づいて定格電力入力を決定する場合があります。これは、10 項の電源入力テストでは、製品が定格電圧で動作する必要があるためです。一部の製品には特殊なケースがある場合があり、これについては後続の章で説明します。 経験豊富な開発チームの場合、製品設計の初期段階で定格入力が決定され、開発者は設計プログラムに従って製品を設計します。また、開発者が設計スキームを持っておらず、製品試作後に定格入力を暫定的に確認するケースもあります。ルームヒーター(石英管ヒーター)などの製品の定格電圧はAC220Vですが、通常はAC220V電源で製品を使用することができ、ヒーターの動作状態は最高レベルの熱に設定されます(首振りやその他の機能がある場合)をオンにする必要もあります)。これは、実際の入力電力、丸め値を定格電力入力として記録します。したがって、第 10 項の電源入力試験を実行する場合、試験値と定格値が規格で指定された偏差範囲を超えた場合、第 10 項の要件を満たすように定格入力電力を変更することができます。 ほとんどの場合、アプライアンスには定格電力入力が与えられます。製品には定格入力電流のみが与えられる場合もありますが、実際のテストでは、規格により製品の動作状態を定格入力電力に基づいて判断することが求められています。このメモの情報に従って入力電力情報を決定することができます。これはまれな状況です。製品のテスト条件が定格入力電力に基づく場合、通常、製品には定格入力電力のラベルが付けられます。製品のメーカーが入力電力定格を指定していない場合でも、サードパーティの試験機関は通常、製品をテストするときに入力電力定格情報を要求します。これは、定格電圧 AC220V、定格電流入力 10A と表示され、定格電力入力のない石英管ルーム ヒーターの仮想的な例です。第 11 項の耐熱試験を実施する場合、規格では定格入力電力の 1.15 倍で製品を動作させることが求められています。この状況では、この記事の注記の情報を使用して定格電力入力を決定できます。暖房器具には通常、定格入力が表示されています。

  • Clause 3 – How to understand the definition of “protective extra-low voltage circuit”

    protective extra-low voltage circuit: earthed circuit operating at safety extra-low voltage which is separated from other circuits by basic insulation and protective screening, double insulation or reinforced insulationNOTE 1 Protective screening is the separation of circuits from live parts by means of an earthed screen.NOTE 2 A protective extra-low voltage circuit is also known as…

  • Clause 3 – How to understand the definition of “protective electronic circuit”

    protective electronic circuit: electronic circuit that prevents a hazardous situation under abnormal operating conditions.NOTE Parts of the circuit may also be used for functional purposes. With the advancement of technology, more and more electronic circuits are being used in household electrical products, and these electronic circuits are usually integrated on PCBs. They use microprocessor chips…

  • |

    If the PCB is sealed with solid sealant, how to determine the creepage distance and clearance?

    functional insulation as well as other insulation exists on circuit boards. Typically, the surface environment of a circuit board is determined to be either Pollution degree 3 or pollution degree 2.If the circuit board is mounted in an electrical box and sealed with a solid sealant, the sealing will look as follows: What should be…

  • 第3項 「相互接続コード」の定義の見方

    相互接続コード࿱アプライアンスの 2 つの部分の間にある外部のフレキシブル コードで、主電源への接続以外の目的で完全なアプライアンスの一部として提供されます接続コードが主電源に接続されていない。これらはアプライアンスの 2 つの部分の間に配置されます。コードは電気エネルギーをある部分から別の部分に伝導できます。相互接続コードの概念は、相互接続コードによって引き起こされる危険を軽減するためにここで定義されます。規格 25.23 および 25.24 では、相互接続コードの要件が規定されています。標準要件の観点から、この規格では主に、機器の外部コード、使用中に発生する可能性のある引っ張り、および電源コードが耐える可能性のあるその他の同様の使用条件が考慮されています。したがって、電源コード以外の外部からアクセス可能なコードのほとんどは相互接続コードとみなすことができます。注1は代表的な例です。 床置き型ミストファンは下図のように、上図の壁掛け型ミストファンとは構造が異なりますが、機能は同じです。床置き型ミストファンは一体構造ですが、ファンヘッドと下の水タンクを繋ぐコードが外側にあります(コードは真ん中の支柱を通します)。この種の接続については、相互接続コードでもあると著者は考えています。 下図に示すように、分割型壁掛け型エアコン室内機の表示基板と主制御基板間の一般的なリード線です。トップカバーを手で開けばリード線に触れることができますが、通常の使用中はリード線が機器の内部にあるため、相互接続コードとはみなされません。ただし、リードは依然として第 22.8 条の要件を満たす必要があります。 アプライアンスはコード セットによって供給され、パーツ A とパーツ B で構成されます。パーツ B は手持ち式で、相互接続コードによってパーツ A に接続されます。この情報は CTL 決定 OD-5002-F3:2021 に基づいています。 As shown in the figure below, a floor standing mist fan has a different structure from the wall mount mist fan shown in the figure above, but…

  • Clause 3 – How to understand the definition of “electronic component”

    electronic circuit: circuit incorporating at least one electronic component. The standard references electronic circuits in clause 19.11, clause 19.11.1, and clause 22.5. These requirements are additional to those for electronic circuits. The standard recognizes that electronic circuits alone cannot provide adequate protection. Electronic circuits may be susceptible to interference and malfunction, or they may be…