Clause 3 – How to understand the definition of “motor-operated appliance”

motor-operated appliance: appliance incorporating motors but without any heating element
Note 1 to entry: Magnetically driven appliances are considered to be motor-operated appliances.

Household electrical appliances usually use heating elements or motors to complete their designed functions. The main functions are heating, such as heating food or air, and rotation or mechanical movement of products, such as blenders and fans. The realization of these two functions is basically completed by heating elements or motors. For appliances with only motors without heating element is motor-operated applaince. Common motors include AC asynchronous motors for air conditioners and fans, series motors used in blenders or hair dryers, shaded pole motors, synchronous motors, stepper motors, DC brushless motors, DC variable frequency motors, etc. It is necessary for us to briefly introduce the characteristics of various motors.

Shaded pole motor/squirrel cage motor:
The shaded pole motor/squirrel cage motor is the simplest type of unidirectional AC motor and usually uses a squirrel cage-type skewed slot cast aluminum rotor.

The shaded pole motor/squirrel cage motor has the following key characteristics:

  1. Simple Structure: The design is relatively straightforward, consisting mainly of a stator and rotor, with the rotor typically made of aluminum or copper bars short-circuited at both ends.
  2. High Efficiency: These motors have high efficiency, especially under rated load conditions, effectively converting electrical energy into mechanical energy.
  3. Low Maintenance: With no brushes or slip rings, squirrel cage motors require minimal maintenance, leading to stable operation and a long lifespan.
  4. Self-Starting Ability: Squirrel cage motors can start directly from the power supply, exhibiting good self-starting characteristics.
  5. High Starting Torque: They can provide significant starting torque, making them suitable for various industrial applications.
  6. Strong Load Adaptability: These motors can handle different load conditions well, particularly performing effectively under variable load situations.
  7. Cost-Effectiveness: Compared to other types of motors, squirrel cage motors have lower manufacturing costs and offer good economic value due to their high efficiency and low maintenance needs.
  8. Wide Applications: They are commonly used in pumps, fans, conveyors, compressors, and a variety of other industrial and commercial equipment.

Single-phase asynchronous motors:

Single-phase asynchronous motors have the following characteristics:

  1. Simple Structure: These motors have a straightforward design, typically consisting of a stator, rotor, and auxiliary winding.
  2. Starting Method: Single-phase power cannot create a rotating magnetic field on its own, so these motors usually require additional starting windings or capacitors for startup, commonly using capacitor start or split-phase methods.
  3. Speed Characteristics: The speed is relatively stable, but compared to three-phase motors, the speed-load characteristics and efficiency are generally lower.
  4. Power Range: They typically operate at lower power levels, making them suitable for applications in household appliances and small machinery.
  5. Noise and Vibration: They may produce more noise and vibration during operation compared to three-phase motors.
  6. Starting Torque: The starting torque is usually lower, which can hinder direct startup under heavy load conditions.
  7. Cost-Effectiveness: Manufacturing and maintenance costs are typically lower, making them ideal for household appliances and small devices.
    Application Range: Commonly used in small fans, air conditioners, refrigerators, and pumps in both home and small industrial settings.

Squirrel cage motors typically have higher efficiency compared to single-phase asynchronous motors. This is mainly due to their design, which allows for better performance under load and reduced losses. Squirrel cage motors operate more efficiently, especially at full load, while single-phase motors may experience lower efficiency, particularly at partial loads. Therefore, for applications requiring higher efficiency and consistent performance, squirrel cage motors are usually the preferred choice.

DC Reduction step gear stepper motor:

A DC reduction step gear stepper motor combines the characteristics of a stepper motor with a geared reduction system. This type of motor is valued for its precision control and increased torque, making it suitable for applications that require slow, controlled, and high-torque movement. Here are its key characteristics:

  1. Precise Positioning: With its stepwise rotation, a stepper motor can provide highly accurate positioning, as each step represents a specific increment of rotation. The addition of a reduction gear enhances this accuracy by allowing smaller steps in the output.
  2. Increased Torque: The reduction gear mechanism increases torque output by reducing the speed of the motor. This is beneficial for applications that require higher torque at lower speeds, such as robotics, CNC machines, and automation systems.
  3. Improved Holding Torque: The motor can maintain its position when not in motion (holding torque), which is ideal for applications that need to hold a load steady without additional power.
  4. Lower Speed, High Precision: Due to the reduction gear, the motor operates at a lower speed but with increased precision. This is useful in applications where controlled, slow movements are required.
  5. Reduction Ratio: The gear reduction system is available in different ratios, allowing users to select the gear ratio that best meets their speed and torque requirements. Common ratios range from 4:1 to 100:1, affecting both torque and resolution.
  6. Steady and Reliable Operation: This type of motor is known for providing stable, repeatable movements. It is less prone to stalling or losing steps, thanks to the torque amplification provided by the reduction gear.
  7. Heat Generation: Geared stepper motors can generate heat during prolonged operation, especially at lower speeds and high loads. Proper ventilation or heat management may be required in demanding applications.
  8. Power Consumption: While stepper motors tend to consume more power than DC motors when holding a position, the gear reduction can reduce the load on the motor, potentially lowering overall power consumption.

Small Synchronous Gear Motor:

Small synchronous gear motors are compact devices that combine a synchronous motor with a gear reduction mechanism. Here are their key characteristics:

  1. Synchronous Operation: The rotor of a synchronous gear motor rotates at the same speed as the rotating magnetic field of the stator. This leads to precise speed control and consistent performance.
  2. Gear Reduction: The integrated gear system reduces the output speed while increasing torque. This is beneficial for applications requiring high torque at lower speeds, such as in robotics or automation.
  3. High Efficiency: Synchronous motors are generally more efficient than their induction counterparts, especially under load. This efficiency translates to lower energy consumption in applications.
  4. Compact Size: Small synchronous gear motors are designed to be space-efficient, making them suitable for applications with limited space, like small appliances, toys, and robotic systems.
  5. Low Noise: These motors typically operate quietly compared to other types of motors, making them ideal for noise-sensitive environments.
  6. Stable Operation: They provide stable and reliable operation with minimal vibration, contributing to precise movements.
  7. Variable Speed Control: With the right control system, synchronous gear motors can achieve variable speed operation, allowing for adaptability in different applications.
  8. High Holding Torque: When stopped, they maintain their position effectively, which is important for applications that require precise positioning.
  9. Limited Start-Up Torque: While they perform well under steady conditions, synchronous motors may have lower start-up torque compared to some other motor types. They might need help to start under load.
  10. Wide Range of Applications: Commonly used in robotics, conveyor systems, small appliances, and other applications where controlled motion and space efficiency are essential.

Series motor:

Series motors, a type of DC motor, have distinct characteristics that make them suitable for specific applications. Here are their key characteristics:

  1. High Starting Torque: Series motors produce high starting torque, making them ideal for applications requiring significant initial power, such as in electric vehicles, cranes, and hoists.
  2. Speed-Torque Relationship: The speed of a series motor decreases with an increase in load. As the load increases, the current increases, which in turn increases the magnetic field strength, leading to higher torque but lower speed.
  3. Simple Construction: Series motors have a relatively simple construction, with the armature winding and field winding connected in series. This design contributes to their ease of use and maintenance.
  4. Variable Speed: The speed of a series motor can vary significantly with load changes. While this can be advantageous in certain applications, it can also lead to instability at very low loads, potentially causing the motor to run away (over-speed).
  5. Not Suitable for Constant Speed Applications: Due to the significant variation in speed with changes in load, series motors are not ideal for applications where constant speed is crucial.
  6. High Current Draw: Series motors draw a high current at startup, which can necessitate the use of appropriate fuses or circuit breakers to prevent damage.
  7. Field Weakening: In some applications, it’s possible to weaken the field by reducing the current in the field winding, allowing for increased speed under light loads, although this can decrease efficiency.
  8. Good for Applications with Variable Load: Series motors are well-suited for applications where the load changes frequently, such as in trains, lifts, and electric vehicles.
  9. Limited Efficiency: Generally, series motors are less efficient than some other types of motors, especially under varying load conditions.
  10. Brush Wear: The wear on brushes can be significant in series motors due to the high current and the nature of operation, which may require more frequent maintenance.

Series motors are commonly used in blenders, hair dryers, vacuum cleaners, and other applications that require high starting torque.

Similar Posts

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ไฟล์แนบประเภท X, ประเภท Y, ประเภท Z”

    สิ่งที่แนบประเภท X: การเชื่อมต่อสายไฟเสร็จสมบูรณ์ในพื้นที่ที่เตรียมไว้เป็นพิเศษในเครื่องใช้ไฟฟ้า ดังนั้นเมื่อเปลี่ยนสายไฟจะไม่สัมผัสส่วนอื่นใดนอกจากแผงขั้วต่อและสายภายใน สกรูที่ยึดสายไฟเป็นสกรูหัวแฉกหรือหัวแบนธรรมดา การเปลี่ยนสายไฟให้ดำเนินการภายในช่วงที่ควบคุมได้ สายไฟที่ผู้ใช้ทั่วไปแทนที่นั้นค่อนข้างเรียบง่ายและใช้งานได้ การแนบประเภท Y: เมื่อเปลี่ยนสายไฟ โดยทั่วไปจำเป็นต้องเปิดโครงโครงสร้างของเครื่องใช้ไฟฟ้า และยึดตัวเรือนเหล่านี้ด้วยสกรูพิเศษ เช่น สกรูหกเหลี่ยม หลังจากเปิดโครงโครงสร้างของเครื่องแล้ว ชิ้นส่วนทดแทนอาจสัมผัสชิ้นส่วนที่เคลื่อนไหวที่เป็นอันตรายหรือชิ้นส่วนอื่นๆ ที่มีไฟฟ้าภายในเครื่องได้ ในกรณีนี้ จะปลอดภัยกว่าหากกำหนดการเชื่อมต่อเป็นเอกสารแนบประเภท Y และกำหนดให้ผู้เชี่ยวชาญเปลี่ยนสายไฟ โดยปกติแล้ว สกรูยึดจะเป็นสกรูธรรมดาที่ผู้ใช้ทั่วไปสามารถใช้งานได้ แต่หากสัมผัสชิ้นส่วนที่เป็นอันตรายได้ในระหว่างการเปลี่ยนสายไฟ โดยทั่วไปจะกำหนดให้เป็นสิ่งที่แนบมาประเภท Y ไฟล์แนบประเภท Z ดูคำอธิบายและตัวอย่างใน 3.2.6. type Z attachment, see the explanation and examples in 3.2.6.

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “ฉนวนเสริม” ได้อย่างไร

    จากหมายเหตุ สามารถทดสอบฉนวนเสริมและฉนวนพื้นฐานได้ทีละชิ้น ซึ่งหมายความว่าฉนวนเสริมและฉนวนพื้นฐานสามารถแยกแยะและแยกออกจากกันได้อย่างง่ายดาย ในทำนองเดียวกัน หากฉนวนประกอบด้วยหลายชั้นหรือหลายฉนวนที่ไม่สามารถแยกและแยกแยะได้ง่าย แต่เทียบเท่ากับฉนวนสองชั้นตามผลของฉนวนจริง ก็สามารถนิยามได้ว่าเป็นฉนวนเสริม นอกจากนี้ หากเป็นเพียงชั้นเดียวหรือฉนวนอิเล็กทริกเดียว ผลของฉนวนจะเทียบเท่ากับฉนวนสองชั้น ก็ยังสามารถกำหนดเป็นฉนวนเสริมได้ดังแสดงในสองภาพด้านล่าง ภาพซ้ายเป็นภาพด้านหลังตู้เย็น แผงวงจรด้านในสามารถมองเห็นได้ผ่านตะแกรงโลหะในภาพด้านซ้าย และภาพภายในคือภาพด้านขวา มีส่วนที่มีกระแสไฟฟ้าอยู่บน PCB และผู้ใช้สามารถสัมผัสกระจังหน้าได้ อากาศระหว่างช่องว่างของกระจังหน้าและชิ้นส่วนที่มีไฟฟ้าบนแผงวงจรอาจทำให้เกิดวงจรนำไฟฟ้าได้ ดังนั้นระยะนี้สามารถกำหนดเป็นระยะห่างด้วยฉนวนเสริมได้ เพราะการกวาดล้างและ nbsp; และ nbsp;ประกอบด้วยห่วงอากาศ ห่วงอากาศไม่สามารถแยกออกได้ และเราไม่รู้ด้วยซ้ำว่าจะแบ่งอากาศนี้ออกเป็นหลายส่วนที่ไหน ที่นี่ต้องสังเกตสองประเด็น ถ้าตะแกรงโลหะไม่ได้ต่อสายดิน อากาศระหว่างตะแกรงและชิ้นส่วนที่มีไฟฟ้าในแผงวงจรต้องเป็นไปตามข้อกำหนดของฉนวนเสริม (ตามข้อกำหนดในข้อ 8.2 สำหรับเครื่องใช้ไฟฟ้าประเภท II) ถ้าตะแกรงโลหะต่อสายดิน ดังนั้นอากาศระหว่างตะแกรงและชิ้นส่วนที่มีกระแสไฟฟ้าในแผงวงจรจะต้องเป็นไปตามข้อกำหนดของฉนวนพื้นฐานเท่านั้น เนื่องจากฉนวนพื้นฐานพร้อมสายดินเป็นอุปกรณ์ Class I ที่มีมาตรการป้องกันสองชั้น และผู้ใช้สามารถสัมผัสชิ้นส่วนโลหะที่ต่อสายดินได้ ปั๊มจุ่มที่แสดงด้านล่างมีโพลมอเตอร์สีเทาอยู่ภายใน โดยมีขดลวดหุ้มด้วยฉนวนสีเหลือง เพื่อป้องกันความเสียหายจากน้ำ สเตเตอร์ของมอเตอร์ทั้งหมดจึงถูกห่อด้วยอีพอกซีเรซิน หลังจากที่พันขดลวดแล้ว จะไม่สามารถทดสอบฉนวนพื้นฐานและฉนวนเสริมได้อย่างมีประสิทธิภาพ ก่อนที่จะเทอีพอกซีเรซิน ฉนวนสีเหลืองถือได้ว่าเป็นฉนวนพื้นฐาน และอีพอกซีเรซินถือได้ว่าเป็นฉนวนเสริม อย่างไรก็ตาม เมื่อเทอีพอกซีเรซินลงในตัวเรือนปั๊ม มันจะยึดติดกับวัสดุฉนวนสีเหลืองอย่างแน่นหนา และไม่สามารถแยกวัสดุทั้งสองออกเพื่อการประเมินได้ เช่น การประเมินการทดสอบความแข็งแรงทางไฟฟ้า ดังนั้นฉนวนเสริมจึงถูกสร้างขึ้นตั้งแต่ขดลวดปั๊มไปจนถึงพื้นผิวอีพอกซีเรซินที่สามารถเข้าถึงได้จากภายนอก…

  • Clause 3 – How to understand the definition of “protective device”

    The standard emphasizes “abnormal operation” here. Only devices that operate under “abnormal operation” conditions can be defined as protective devices. Therefore, there are many types of protective devices, including overheating protection devices, overcurrent protection devices, and overpressure protection devices. Overheating protection devices include the thermal link, non- self-resetting thermal cut-out, self-resetting thermal cut-out, thermal cut-out,…

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “ความต้านทานเชิงป้องกัน” ได้อย่างไร

    กรณีที่ 1: อิมพีแดนซ์ป้องกันทั้งสองเชื่อมต่อระหว่างขดลวดปฐมภูมิและขดลวดทุติยภูมิของหม้อแปลง T2 เส้นประในรูปด้านล่างแสดงถึงการแยกระหว่างส่วนแรงดันไฟฟ้าทำงาน 220-240V และส่วนแรงดันไฟฟ้าทำงานต่ำ (SELV)รูปด้านล่างคือแผนภาพวงจรของเครื่องกำเนิดไอออนลบ ตัวต้านทานสองตัวที่เลือกโดยสี่เหลี่ยมสีแดงนั้นเป็นอิมพีแดนซ์ในการป้องกันโดยทั่วไป ในภาพด้านล่าง มีอิมพีแดนซ์ป้องกัน CY1 และ CY2 หรือไม่ จากคำจำกัดความของมาตรฐาน อิมพีแดนซ์ป้องกันถูกใช้ในโครงสร้างประเภท II ที่มีการต่อสายดิน หากการต่อสายดินที่นี่ถูกกำหนดให้เป็นการต่อสายดินการป้องกัน เห็นได้ชัดว่า CY1 และ CY2 ไม่สามารถกำหนดเป็นอิมพีแดนซ์การป้องกันได้ เนื่องจากอิมพีแดนซ์การป้องกันถูกใช้ในการก่อสร้างคลาส II และนี่คือการก่อสร้างคลาส I ถ้าการต่อสายดินและ nbsp;ในที่นี้ถูกกำหนดให้เป็นการต่อสายดินเชิงฟังก์ชัน แสดงว่ามีปัญหาสองประการ ประการแรก นี่คือโครงสร้างคลาส I ดังนั้น CY1 และ CY2 จึงไม่สามารถกำหนดเป็นอิมพีแดนซ์การป้องกันได้ ประการที่สอง หากเป็นโครงสร้างคลาส II ก็สามารถกำหนด CY1 และ CY2 เป็นอิมพีแดนซ์การป้องกันได้ จากนั้นจึงจำเป็นต้องปฏิบัติตามข้อกำหนดที่เกี่ยวข้องของอิมพีแดนซ์การป้องกัน ความเห็นส่วนตัวของฉันคือ CY1 และ CY2 ไม่ใช่อิมพีแดนซ์ป้องกัน และเราสามารถถือเป็นฉนวนพื้นฐานได้โดยตรง…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ช่วงแรงดันไฟฟ้าที่กำหนด”

    ช่วงแรงดันไฟฟ้าที่ผู้ผลิตกำหนดให้กับเครื่องใช้ไฟฟ้า แสดงด้วยขีดจำกัดล่างและบน:คำจำกัดความนี้เป็นส่วนขยายของคำจำกัดความของ พิกัดแรงดันไฟฟ้า พิกัดแรงดันไฟฟ้าพิกัดแรงดันไฟฟ้า แต่ไม่ค่อยมีการกำหนดแรงดันไฟฟ้าที่กำหนดตัวอย่างเช่น ผลิตภัณฑ์ที่ออกแบบมาสำหรับตลาดเป้าหมายสำหรับตลาดประเทศสมาชิก EU ทั้งหมดของยุโรป ประเทศสมาชิก EU ส่วนใหญ่ของแรงดันไฟฟ้าสาธารณูปโภคคือ AC 230V แต่มีบางประเทศเป็น AC 240V หากเป็นเพียงข้อกำหนดแยกต่างหาก ของแรงดันไฟฟ้าที่กำหนดของ AC230V หรือ AC240V ดังนั้นผลิตภัณฑ์นี้ไม่สามารถใช้กับแรงดันไฟฟ้าที่ใช้ในอาคารแตกต่างจากแรงดันไฟฟ้าที่กำหนดของประเทศได้ จากสถานการณ์นี้ เราสามารถระบุแรงดันไฟฟ้าที่กำหนดในรูปแบบของช่วง AC220-240V ซึ่งครอบคลุม AC220V และ AC230V และ AC240V เพื่อให้ผลิตภัณฑ์ที่เกี่ยวข้องสามารถนำมาใช้ในประเทศที่มีแรงดันไฟฟ้าสาธารณูปโภคทั้งสามนี้ ในที่นี้ AC220-240V หรือ 220-240V~ เป็นรูปแบบทั่วไป นอกจากนี้ จะมี 220-230V~ หรือ 380V-415V~ หรือ 100-240V~ (สถานการณ์ส่วนใหญ่นี้เกิดขึ้นในการใช้อะแดปเตอร์ที่ขับเคลื่อนโดยแรงดันไฟฟ้าอินพุตที่กำหนดของอะแดปเตอร์) และอื่นๆ เนื่องจากแรงดันไฟฟ้าที่กำหนดของผลิตภัณฑ์ถูกตั้งค่าในช่วง ข้อกำหนดด้านความปลอดภัยในช่วงแรงดันไฟฟ้านี้จึงต้องได้รับการประเมินตามมาตรฐาน, but rarely a defined rated voltage. For…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ความปลอดภัยแรงดันไฟฟ้าต่ำพิเศษ”

    หมายเหตุ 2 แรงดันไฟฟ้าต่ำพิเศษเพื่อความปลอดภัยเรียกอีกอย่างว่า SELVจากชื่อ – แรงดันไฟฟ้าต่ำพิเศษด้านความปลอดภัย คำจำกัดความนี้มีคำว่า “ความปลอดภัย” มากกว่าแรงดันไฟฟ้าต่ำพิเศษ อย่างไรก็ตาม ในมาตรฐานนี้ เราได้อธิบายไว้ก่อนหน้านี้แล้วว่าแนวคิดเรื่องความปลอดภัยเป็นแนวคิดที่สัมพันธ์กัน ซึ่งได้รับการอธิบายไว้ในคำนำ-1 ที่นี่ เราต้องเพิ่มเติมว่า SELV มีข้อบังคับเกี่ยวกับค่าแรงดันไฟฟ้า แรงดันไฟฟ้าที่ระบุในที่นี้คือค่าประสิทธิผลของแรงดันไฟฟ้า โดยปกติ ค่าพีคของแรงดันไฟฟ้าจะสูงกว่าค่าประสิทธิผล และขีดจำกัดแรงดันไฟฟ้าที่ระบุในข้อ 8.1.4 เป็นข้อกำหนดสำหรับค่าพีค เราจะอธิบายข้อกำหนดการทดสอบโดยละเอียดในข้อ 8.1.4 หมายเหตุ 2 ของย่อหน้าแรกในข้อ 3 ให้ประโยค “หมายเหตุ 2 เมื่อใช้เงื่อนไข “แรงดันไฟฟ้า” และ “ปัจจุบัน” จะมีค่า r.m.s. เว้นแต่จะระบุไว้เป็นอย่างอื่น” ดังแสดงในรูปด้านล่าง หม้อแปลงไฟฟ้ามีขายึดพลาสติกสามตัววางในแนวตั้งลงในแผ่นดิสก์เพื่อแยกขดลวดปฐมภูมิและขดลวดทุติยภูมิ (ขดลวดปฐมภูมิและขดลวดทุติยภูมิถูกพันด้วยเทปพลาสติกสีน้ำเงินด้านนอก) และขดลวดปฐมภูมิและขดลวดทุติยภูมิคือ แยกตัวออกจากร่างกายเราจะอธิบายโครงสร้างของหม้อแปลงแยกความปลอดภัยโดยละเอียดในโพสต์ถัดไป Here, we need to add that SELV has regulations on voltage…