Clause 3 – How to understand the definition of “battery-operated appliance”

(IEC 60335-1 Ed. 5.1) battery-operated appliance: appliance deriving its energy from batteries enabling the appliance to perform its intended function without a mains connection.
(IEC 60335-1 Ed. 6)battery-operated appliance: appliance deriving its energy from batteries enabling the appliance to perform its intended function without a supply connection
Note 1 to entry: A battery-operated appliance can have a supply connection.
Standards prior to version 5.1 did not have definitions for battery-operated appliance.

There is no mention of battery-operated appliances in the first clause-scope) of the standard prior to version 5.0.
More and more products will be powered by batteries. This is especially true for personal care products, including razors, hair stylers, etc. Battery operated appliances are mainly appliances that can only derive energy from a battery. The battery can be a rechargeable battery, a dry cell battery, and the battery can be installed in the contents of the appliance or placed in a battery box. It should be emphasized that the appliance is not capable of obtaining electrical energy through a supply connection. A supply connection includes a connection to supply mains or a connection to a solar panel. Batteries can be supplied via a connection to supply mains or a connection to a solar panel.
In version 5.1, the term “mains connection” is used to refer to municipal power supply. In version 6.0, the term used was changed to “supply connection”, and there is a comment in the redline version of the standard that explains that “supply connection” includes a connection to supply mains or a connection to a solar panel.

Similar Posts

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “ความต้านทานเชิงป้องกัน” ได้อย่างไร

    กรณีที่ 1: อิมพีแดนซ์ป้องกันทั้งสองเชื่อมต่อระหว่างขดลวดปฐมภูมิและขดลวดทุติยภูมิของหม้อแปลง T2 เส้นประในรูปด้านล่างแสดงถึงการแยกระหว่างส่วนแรงดันไฟฟ้าทำงาน 220-240V และส่วนแรงดันไฟฟ้าทำงานต่ำ (SELV)รูปด้านล่างคือแผนภาพวงจรของเครื่องกำเนิดไอออนลบ ตัวต้านทานสองตัวที่เลือกโดยสี่เหลี่ยมสีแดงนั้นเป็นอิมพีแดนซ์ในการป้องกันโดยทั่วไป ในภาพด้านล่าง มีอิมพีแดนซ์ป้องกัน CY1 และ CY2 หรือไม่ จากคำจำกัดความของมาตรฐาน อิมพีแดนซ์ป้องกันถูกใช้ในโครงสร้างประเภท II ที่มีการต่อสายดิน หากการต่อสายดินที่นี่ถูกกำหนดให้เป็นการต่อสายดินการป้องกัน เห็นได้ชัดว่า CY1 และ CY2 ไม่สามารถกำหนดเป็นอิมพีแดนซ์การป้องกันได้ เนื่องจากอิมพีแดนซ์การป้องกันถูกใช้ในการก่อสร้างคลาส II และนี่คือการก่อสร้างคลาส I ถ้าการต่อสายดินและ nbsp;ในที่นี้ถูกกำหนดให้เป็นการต่อสายดินเชิงฟังก์ชัน แสดงว่ามีปัญหาสองประการ ประการแรก นี่คือโครงสร้างคลาส I ดังนั้น CY1 และ CY2 จึงไม่สามารถกำหนดเป็นอิมพีแดนซ์การป้องกันได้ ประการที่สอง หากเป็นโครงสร้างคลาส II ก็สามารถกำหนด CY1 และ CY2 เป็นอิมพีแดนซ์การป้องกันได้ จากนั้นจึงจำเป็นต้องปฏิบัติตามข้อกำหนดที่เกี่ยวข้องของอิมพีแดนซ์การป้องกัน ความเห็นส่วนตัวของฉันคือ CY1 และ CY2 ไม่ใช่อิมพีแดนซ์ป้องกัน และเราสามารถถือเป็นฉนวนพื้นฐานได้โดยตรง…

  • Clause 3 – How to understand the definition of “protective electronic circuit”

    protective electronic circuit: electronic circuit that prevents a hazardous situation under abnormal operating conditions.NOTE Parts of the circuit may also be used for functional purposes. With the advancement of technology, more and more electronic circuits are being used in household electrical products, and these electronic circuits are usually integrated on PCBs. They use microprocessor chips…

  • Clause 3 – How to understand the definition of “detachable power supply part”

    detachable power supply part: part of the appliance the output of which is intended to be detachable from the class III construction part of the appliance.Note 1 to entry: Means of detachment are a flexible cord and connector or an appliance outlet fitted to the detachable power supply part. This actually defines a detachable adapter….

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ความถี่ที่กำหนด”

    โดยทั่วไป ความถี่ที่กำหนดคือความถี่สาธารณูปโภคมาตรฐานของประเทศตลาดเป้าหมาย ณ เวลาที่ออกแบบผลิตภัณฑ์ เนื่องจากทั่วโลก มีเพียงสองความถี่ยูทิลิตี้คือ 50Hz และ 60Hz ค่าสามารถเป็นได้เพียง 50Hz หรือ 60Hz หรือทั้ง 50 และ 60Hz ความถี่ที่กำหนด กำลังไฟฟ้าเข้าที่กำหนดหรือกำลังไฟฟ้าที่กำหนด แรงดันไฟฟ้าที่กำหนด ฯลฯ เป็นพารามิเตอร์พื้นฐานที่กำหนดลักษณะของอุปกรณ์ ซึ่งได้มาจากความต้องการของตลาดเป้าหมายตลอดจนเงื่อนไขด้านสาธารณูปโภค เมื่อเราทดสอบตามมาตรฐาน เราจะกำหนดเงื่อนไขการทดสอบตามพารามิเตอร์เหล่านี้ ดังนั้นต้องยืนยันพารามิเตอร์เหล่านี้ก่อนการทดสอบ ไม่เช่นนั้นจะทำให้เกิดการทำงานซ้ำซ้อน และสร้างผลการทดสอบที่ไม่ถูกต้องWhen we test according to the standard, we set our test conditions according to these parameters. Therefore, these parameters must be confirmed before the test, otherwise it will…

  • Clause 3 – How to understand the definition of “protective device”

    protective device: device, the operation of which prevents a hazardous situation under abnormal operation conditions The standard emphasizes “abnormal operation” here. Only devices that operate under “abnormal operation” conditions can be defined as protective devices. Therefore, there are many types of protective devices, including overheating protection devices, overcurrent protection devices, and overpressure protection devices. Overheating…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ช่วงความถี่ที่กำหนด”

    ความถี่ที่กำหนดในรูปแบบของช่วง โดยทั่วไปคือ 50-60 Hz แต่ทุกประเทศในโลกมีความถี่หลัก 50 Hz หรือ 60 Hz จึงไม่มีค่าความถี่กลาง ดังนั้น คำจำกัดความจึงไม่มีความหมายมากนัก อย่างไรก็ตาม ยังมีผู้ซื้อหรือผู้ผลิตที่ให้ช่วงความถี่ในรูปแบบ 50-60Hz ในความคิดของฉัน แม้จะพิจารณาความผันผวนของความถี่ที่เกิดจากแรงดันไฟฟ้าของอาคารที่ไม่เสถียร 50-60Hz ก็ไม่ได้คำนึงถึงสถานการณ์ที่น้อยกว่า 50Hz หรือมากกว่า 60Hz ดังนั้น ฉันขอแนะนำให้ทำเครื่องหมายความถี่ที่กำหนดเป็น 50/60Hz โดยตรงTherefore, I recommend marking the rated frequency as 50/60Hz directly.