Clause 3 – How to Understand the Definition of “Intentionally Weak Part”

intentionally weak part: A part intended to rupture under abnormal operating conditions to prevent the occurrence of a condition that could impair compliance with this standard.
NOTE: Such a part may be a replaceable component, such as a resistor or capacitor, or a part of a component to be replaced, such as an inaccessible thermal link incorporated into a motor.

Clause 24.1.8 of the standard states: The relevant standard for thermal links is IEC 60691. Thermal links that do not comply with IEC 60691 are considered intentionally weak parts for the purposes of Clause 19.

Combining the definitions in Clause 3 and Clause 24.1.8, it’s easy to conclude that if a thermal link complies with IEC 60691, it’s not an intentionally weak part. Conversely, if a thermal link does not comply with IEC 60691, it can be an intentionally weak part. However, Clause 19.1 states the following: If a heating element complies with IEC 60691, it is considered an intentionally weak part. If an element or an intentionally weak part becomes permanently open-circuited, the relevant test is repeated on a second sample. This second test shall be terminated in the same mode unless the test is otherwise satisfactorily completed.

Thus, we can understand this: for some protective devices, such as current fuses and thermal links, if these components do not have approval certificates according to their corresponding standards and therefore do not comply with the standards, but they provide protection during the abnormal tests in Clause 19, they can be considered intentionally weak parts. However, sometimes the protective function is not provided by protective devices such as current fuses and thermal links, but rather by resistors or capacitors. If these components exhibit an open circuit during testing, breaking the circuit and triggering protection, typically during the tests in Clause 19.11.2, then resistors or capacitors can be considered intentionally weak parts. With technological advancements and the reduction in the cost of protective devices, most manufacturers rarely use resistors or capacitors as intentionally weak parts. However, some IPM modules that power high-current inverter motors or inverter motor-compressors may become intentionally weak parts because the IPM will burn out during the lock-rotor test of such motors.

Similar Posts

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “การทำงานผิดปกติที่เป็นอันตราย” ได้อย่างไร

    ตัวอุปกรณ์ไม่ทำงานตามที่ระบุไว้และอาจเป็นอันตรายต่อความปลอดภัย เช่นพัดลม ตัวเก็บประจุสตาร์ทของมอเตอร์อะซิงโครนัส AC ภายในล้มเหลวในรูปแบบของไฟฟ้าลัดวงจรหรือวงจรเปิด ในกรณีเครื่องปรับอากาศ ช่องระบายของท่อระบายน้ำด้านในถูกปิดกั้น ส่งผลให้ระบายน้ำไม่ออก ส่งผลให้น้ำล้น ประเด็นสำคัญในที่นี้คือการทำความเข้าใจ “การดำเนินการโดยไม่ตั้งใจ” คำตรงข้ามของ “ไม่ได้ตั้งใจ” คือ “ตั้งใจ” โดยทั่วไปแล้ว ไม่มีข้อกำหนดในมาตรฐานสำหรับ “การทำงานที่ตั้งใจไว้” เอาล่ะ ฉันขอยกตัวอย่างที่น่าสยดสยองให้กับคุณ หากมีคนใช้เตารีดไฟฟ้าตีศีรษะผู้อื่น มาตรฐานไม่ได้กำหนดว่าถึงแม้เราจะใช้เตารีดไฟฟ้า เราก็ไม่ควรทำร้ายศีรษะของบุคคลนั้นHere, let me give you a horrible example. If someone uses an electric iron to hit another person’s head, the standard does not require that even if we use the electric iron, we…

  • Clause 3 – How to understand the definition of “thermostat”

    thermostat: temperature-sensing device, the operating temperature of which may be either fixed or adjustable and which during normal operation keeps the temperature of the controlled part between certain limits by automatically opening and closing a circuit. The thermostat itself does not control the temperature, the thermostat senses the temperature and controls the temperature by switching…

  • Clause 3 – How to understand the definition of “portable appliance”

    portable appliance: appliance that is intended to be moved while in operation or an appliance, other than a fixed appliance, having a mass less than 18 kg. This item is relatively easy to understand. Products that are less than 18kg are relatively light, so they are easy to move during operation, including humidifiers, fans, air…

  • Clause 3 – How to understand the definition of “built-in appliance”

    built-in appliance: fixed appliance intended to be installed in a cabinet, in a prepared recess in a wall or in a similar location. Here, because the appliance must be installed in a reserved position (usually a cubic space with only one side open), it is a fixed installation and can be regarded as a fixed…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “กำลังไฟฟ้าเข้าพิกัด”

    กำลังไฟฟ้าเข้าที่ผู้ผลิตกำหนดให้กับเครื่องหมายเหตุ 1: ถ้าไม่ได้กำหนดกำลังไฟฟ้าเข้าให้กับเครื่องใช้ไฟฟ้า กำลังไฟฟ้าเข้าที่กำหนดสำหรับเครื่องทำความร้อนและเครื่องใช้ไฟฟ้าแบบรวมจะเป็นกำลังไฟฟ้าเข้าที่วัดเมื่อจ่ายเครื่องใช้ไฟฟ้าที่แรงดันไฟฟ้าที่กำหนดและทำงานภายใต้การทำงานปกติในกรณีส่วนใหญ่ อุปกรณ์จะได้รับกำลังไฟฟ้าเข้าที่กำหนด บางครั้ง ผลิตภัณฑ์จะได้รับเฉพาะกระแสไฟเข้าที่กำหนดเท่านั้น แต่ในระหว่างการทดสอบจริง มาตรฐานกำหนดให้ต้องพิจารณาสภาพการทำงานของผลิตภัณฑ์ตามกำลังไฟฟ้าเข้าที่กำหนด จากนั้นจึงจะสามารถกำหนดข้อมูลกำลังไฟฟ้าเข้าตามข้อมูลในหมายเหตุนี้ได้ นี่เป็นสถานการณ์ที่หายาก หากเงื่อนไขการทดสอบของผลิตภัณฑ์เป็นไปตามกำลังไฟฟ้าเข้าที่กำหนด โดยปกติแล้วผลิตภัณฑ์จะมีป้ายกำกับว่ากำลังไฟฟ้าเข้าที่กำหนด แม้ว่าผู้ผลิตผลิตภัณฑ์จะไม่ระบุพิกัดกำลังไฟฟ้าเข้า แต่ห้องปฏิบัติการทดสอบของบุคคลที่สามมักจะขอข้อมูลพิกัดกำลังไฟฟ้าเข้าเมื่อทำการทดสอบผลิตภัณฑ์ ต่อไปนี้คือตัวอย่างสมมุติของเครื่องทำความร้อนในห้องที่ใช้หลอดควอทซ์ซึ่งมีป้ายกำกับว่ามีแรงดันไฟฟ้าพิกัด AC220V และอินพุตกระแสไฟพิกัดอยู่ที่ 10A โดยไม่มีกำลังไฟเข้าพิกัด เมื่อทำการทดสอบความร้อนตามข้อ 11 มาตรฐานกำหนดให้ผลิตภัณฑ์ทำงานที่ 1.15 เท่าของกำลังไฟฟ้าเข้าที่กำหนด ในสถานการณ์นี้ สามารถกำหนดกำลังไฟฟ้าเข้าพิกัดได้โดยใช้ข้อมูลในหมายเหตุของบทความนี้ อุปกรณ์ทำความร้อนมักจะทำเครื่องหมายกำลังไฟฟ้าเข้าพิกัด In most cases, the appliance is given a rated powerinput. Sometimes, the product is only given a rated input current, but during actual testing, standards require that…

  • ข้อ 3 – วิธีทำความเข้าใจคำจำกัดความของ “ความถี่ที่กำหนด”

    โดยทั่วไป ความถี่ที่กำหนดคือความถี่สาธารณูปโภคมาตรฐานของประเทศตลาดเป้าหมาย ณ เวลาที่ออกแบบผลิตภัณฑ์ เนื่องจากทั่วโลก มีเพียงสองความถี่ยูทิลิตี้คือ 50Hz และ 60Hz ค่าสามารถเป็นได้เพียง 50Hz หรือ 60Hz หรือทั้ง 50 และ 60Hz ความถี่ที่กำหนด กำลังไฟฟ้าเข้าที่กำหนดหรือกำลังไฟฟ้าที่กำหนด แรงดันไฟฟ้าที่กำหนด ฯลฯ เป็นพารามิเตอร์พื้นฐานที่กำหนดลักษณะของอุปกรณ์ ซึ่งได้มาจากความต้องการของตลาดเป้าหมายตลอดจนเงื่อนไขด้านสาธารณูปโภค เมื่อเราทดสอบตามมาตรฐาน เราจะกำหนดเงื่อนไขการทดสอบตามพารามิเตอร์เหล่านี้ ดังนั้นต้องยืนยันพารามิเตอร์เหล่านี้ก่อนการทดสอบ ไม่เช่นนั้นจะทำให้เกิดการทำงานซ้ำซ้อน และสร้างผลการทดสอบที่ไม่ถูกต้องWhen we test according to the standard, we set our test conditions according to these parameters. Therefore, these parameters must be confirmed before the test, otherwise it will…