Clause 3 – How to understand the definition of “temperature limiter”

temperature limiter: temperature-sensing device, the operating temperature of which may be either fixed or adjustable and which during normal operation operates by opening or closing a circuit when the temperature of the controlled part reaches a pre-determined value.
Note 1 to entry: A temperature limiter does not make the reverse operation during the normal duty cycle of the appliance. It may or may not require manual resetting.

As you can see in the picture above, this is a temperature limiter for an electric kettle. As far as I know, temperature limiter are only used in electric kettles. There may be other household appliances that use a temperature limiter, but the appliance where the temperature limiter is used the most is the kettle. The definition of thermostat is similar to temperature limiter’s definition that is “normal operation”, in that they both specify that the part can only be operated during normal operation.

Similar Posts

  • ข้อ 3 – ข้อกำหนดและคำจำกัดความ: การตีความทั่วไป

    วิธีที่สองมีข้อได้เปรียบมากกว่าในการฝึกอบรมวิศวกรอาวุโสบางคน เลยอยากอธิบายทุกนิยามให้ชัดเจนที่สุดตรงนี้ สิ่งที่ผมอยากบอกคุณก็คือ คำจำกัดความมีความสำคัญมาก และมาตรฐานที่แตกต่างกันก็อาจกำหนดคำเดียวกันให้แตกต่างออกไป ซึ่งทำให้ผู้อ่านต้องเข้าใจอย่างรอบคอบเพื่อหลีกเลี่ยงความสับสนHere, what I want to tell you is that the definition is very important, and different standards may define the same term differently, which requires the reader to grasp carefully to avoid confusion.

  • Clause 3 – How to understand the definition of “detachable part”

    detachable part: part that can be removed or opened without the aid of a tool, a part that is removed or opened in accordance with the instructions for use, even if a tool is needed for removal, or a part that does not fulfil the test of 22.11.NOTE 1 If for installation purposes a part…

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “การทำงานผิดปกติที่เป็นอันตราย” ได้อย่างไร

    ตัวอุปกรณ์ไม่ทำงานตามที่ระบุไว้และอาจเป็นอันตรายต่อความปลอดภัย เช่นพัดลม ตัวเก็บประจุสตาร์ทของมอเตอร์อะซิงโครนัส AC ภายในล้มเหลวในรูปแบบของไฟฟ้าลัดวงจรหรือวงจรเปิด ในกรณีเครื่องปรับอากาศ ช่องระบายของท่อระบายน้ำด้านในถูกปิดกั้น ส่งผลให้ระบายน้ำไม่ออก ส่งผลให้น้ำล้น ประเด็นสำคัญในที่นี้คือการทำความเข้าใจ “การดำเนินการโดยไม่ตั้งใจ” คำตรงข้ามของ “ไม่ได้ตั้งใจ” คือ “ตั้งใจ” โดยทั่วไปแล้ว ไม่มีข้อกำหนดในมาตรฐานสำหรับ “การทำงานที่ตั้งใจไว้” เอาล่ะ ฉันขอยกตัวอย่างที่น่าสยดสยองให้กับคุณ หากมีคนใช้เตารีดไฟฟ้าตีศีรษะผู้อื่น มาตรฐานไม่ได้กำหนดว่าถึงแม้เราจะใช้เตารีดไฟฟ้า เราก็ไม่ควรทำร้ายศีรษะของบุคคลนั้นHere, let me give you a horrible example. If someone uses an electric iron to hit another person’s head, the standard does not require that even if we use the electric iron, we…

  • Clause 3 – How to understand the definition of “user maintenance”

    user maintenance: any maintenance operation stated in the instructions for use, or marked on the appliance, that the user is intended to perform. Allowed user-executed operations, the operation guideline was given in user manual, and it could be showed in enclosure of appliance. Since it is a allowed user-executed operation, then additional protective method should…

  • |

    If the PCB is sealed with solid sealant, how to determine the creepage distance and clearance?

    functional insulation as well as other insulation exists on circuit boards. Typically, the surface environment of a circuit board is determined to be either Pollution degree 3 or pollution degree 2.If the circuit board is mounted in an electrical box and sealed with a solid sealant, the sealing will look as follows: What should be…

  • ข้อ 3 – จะเข้าใจคำจำกัดความของ “สายเชื่อมต่อโครงข่าย” ได้อย่างไร

    หมายเหตุ 1: ในเครื่องใช้ไฟฟ้าที่ใช้แบตเตอรี่ ถ้าใส่แบตเตอรี่ไว้ในกล่องแยกต่างหาก สายไฟอ่อนหรือสายอ่อนที่ต่อกล่องกับเครื่องใช้ไฟฟ้าจะถือเป็นสายเชื่อมต่อโครงข่ายสายเชื่อมต่อไม่ได้เชื่อมต่อกับแหล่งจ่ายไฟหลัก ตั้งอยู่ระหว่างสองส่วนของเครื่องใช้ไฟฟ้า สายไฟสามารถนำพลังงานไฟฟ้าจากส่วนหนึ่งไปยังอีกส่วนหนึ่งได้ แนวคิดของสายเชื่อมต่อโครงข่ายมีการกำหนดไว้ที่นี่เพื่อลดอันตรายที่เกิดจากสายเชื่อมต่อโครงข่าย มาตรฐาน 25.23 และ 25.24 กำหนดข้อกำหนดสำหรับสายเชื่อมต่อโครงข่าย จากมุมมองของข้อกำหนดมาตรฐาน มาตรฐานจะพิจารณาถึงสายไฟภายนอกของเครื่องใช้ไฟฟ้าเป็นหลัก การดึงที่อาจเกิดขึ้นระหว่างการใช้งาน และสภาวะการใช้งานอื่นที่คล้ายคลึงกันซึ่งสายไฟอาจทนได้ ดังนั้นสายไฟที่เข้าถึงได้จากภายนอกส่วนใหญ่นอกเหนือจากสายไฟจึงถือเป็นสายเชื่อมต่อโครงข่าย หมายเหตุ 1 เป็นตัวอย่างทั่วไป ผลิตภัณฑ์ที่แสดงในภาพด้านล่างคือพัดลมที่มีฟังก์ชันการทำให้เป็นละออง (เป่าลมออกมาในรูปของหมอก) สายเชื่อมต่อระหว่างส่วนหัวพัดลมด้านบนและส่วนถังน้ำสีขาวด้านล่างถือได้ว่าเป็นสายเชื่อมต่อ ดังแสดงในรูปด้านล่าง พัดลมไอน้ำแบบตั้งพื้นมีโครงสร้างที่แตกต่างจากพัดลมไอน้ำแบบติดผนังดังแสดงในรูปด้านบน แต่มีฟังก์ชั่นเดียวกัน พัดลมไอน้ำแบบตั้งพื้นเป็นโครงสร้างที่สำคัญ แต่มีสายไฟด้านนอกเชื่อมต่อหัวพัดลมกับถังเก็บน้ำด้านล่าง (สายไฟจะผ่านแกนรองรับตรงกลาง) สำหรับการเชื่อมต่อประเภทนี้ผู้เขียนเชื่อว่าเป็นสายเชื่อมต่อโครงข่ายด้วย ดังแสดงในรูปด้านล่าง นี่คือเส้นนำทั่วไประหว่างแผงวงจรแสดงผลและแผงวงจรควบคุมหลักของเครื่องปรับอากาศแบบแยกส่วนภายในอาคาร แม้ว่าสัมผัสสายได้โดยการเปิดฝาครอบด้านบนด้วยตนเอง แต่สายจะอยู่ด้านในเครื่องระหว่างการใช้งานปกติ จึงไม่ถือว่าเป็นสายเชื่อมต่อระหว่างกัน อย่างไรก็ตาม ผู้นำยังคงต้องเป็นไปตามข้อกำหนดของข้อ 22.8. นี่คือกรณีที่เป็นที่ถกเถียงกันมากขึ้น ซึ่งก็คือสายไฟภายในช่องคอมเพรสเซอร์ที่ด้านหลังของตู้เย็น สายไฟในวงกลมสีแดงในรูปด้านล่างถือเป็นสายเชื่อมต่อโดยองค์กรทดสอบหรือห้องปฏิบัติการบุคคลที่สามส่วนใหญ่ ความเห็นส่วนตัวของฉันคือสายไฟในช่องคอมเพรสเซอร์ตู้เย็นไม่ใช่สายเชื่อมต่อ เราสามารถอนุมานเจตนาของมาตรฐานได้จากข้อกำหนด 25.23 และ 25.24 มาตรฐานกำหนดให้สายเชื่อมต่อต้องเป็นไปตามข้อกำหนดของสายไฟ สายไฟสามารถดึงออกได้ จึงต้องทดสอบตามข้อ 25.15 สายไฟมีลักษณะพิเศษคืออยู่ภายนอกตัวเครื่องและสามารถสัมผัสและดึงได้ สายไฟตู้เย็นที่เรากำลังพูดถึงที่นี่ไม่น่าจะแตะต้องได้ และโดยพื้นฐานแล้วจะไม่ถูกดึง เครื่องใช้ไฟฟ้าได้รับมาโดยชุดสายไฟและประกอบด้วยส่วน…